Istruzioni per l’uso e manutenzione
Cod. OQ7.5ARG114 – GB
Emiss. 19-01-11 Rev. 0 - Agg. /
44
POWER SYSTEM SRL
Via dell’Emigrante, 11/13 - 36040 Brendola (VI) Italia
24.3 OIL
CHARACTERISTICS
A mineral oil for hydraulic purposes must be used, or for screw compressors with oil injection, with the addition of oxidation
inhibitors, and having anti-foam and anti-wear properties.
The degree of viscosity must comply with the following table:
Environment temperature
Degree of viscosity
From 0° to 30° C
ISO VG 32
Below 0° C
ISO VG 15
Continuously above 30° C
ISO VG 46
Never mix oils of different makes or types.
If you want to change the make of oil, stop the compressor and depressurize it, completely drain off the existing oil in
the compressor and change the oil filter, then fill the tank with the new oil.
Use only non toxic oils when there is the risk of inhaling the air distributed.
When supplied by Power System, the compressor is filled with POWERFLUID 4000 oil.
Type of oil
Recommended duration (hours)
POWERFUID 2000
2000
POWERFUID 4000
4000
This lubricant is formulated to the highest quality standards and is factory authorized, tested and approved for use in rotary screw
compressors.
Power System lubricants are available through your authorized compressor distributor.
THE IMPROPER USE OF LUBRICANT MAY CAUSE DAMAGE TO THE SYSTEM. IT IS ABSOLUTELY
FORBIDDEN TO MIX LUBRICANTS OF A DIFFERENT TYPE AND BRAND TOGETHER.
INADEQUATE MAINTENANCE WITH THE USE OF SYNTHETIC LUBRICANTS MAY DAMAGE THE
SYSTEM. THE OIL FILTER AND THE CARTRIDGE OF THE SEPARATOR MUST BE CHANGED
REGULARLY TO GUARANTEE MAXIMUM PROTECTION AND EFFICIENCY OF THE
COMPRESSOR.
HANDLING OIL WITHOUT ADEQUATE PROTECTIONS IS VERY DANGEROUS. WEAR PROTECTIVE
GLOVES.
CHECK THE PRESENCE OF CONDENSATE IN THE SEPARATOR TANK EVERY 500 WORKING
HOURS.