background image

You may continue using it after the temperature returns back 
to normal. Meanwhile, find out what factors are causing the
inverter to overheat. Such factors may be poor ventilation, 
ambient temperature, vent, load power, etc. 

21

FUNCTIONS 

(CONTINUED)

Summary of Contents for PS1001

Page 1: ...PURE SINE WAVE POWER INVERTER MODEL PS1001 PS1002 PS1004 PS1005 PS1003 ...

Page 2: ...undersized Do not operate the PURE SINE with damaged or substandard wiring 4 Do not disassemble the Pure sine inverter It contains no user serviceable parts See the WARRANTY section for instructions or obtaining service Attempting to service the Pure sine inverter yourself may result in a risk of electrical shock or fire Internal capacitors remain charged after all power is disconnected 5 To reduc...

Page 3: ...equipment contains components which tend to produce arcs or sparks To prevent fire or explosion do not install the Pure sine inverter in compartments containing batteries flammable materials or in locations that require ignition protected equipment This includes any space containing gasoline powered machinery fuel tanks as well as joints fittings or other connections between components of the fuel...

Page 4: ...to weld metal to skin causing severe burn 5 Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes 6 Wear complete eye protection and clothing protection Avoid touching your eyes while working near the batteries 7 If battery acid contacts skin or clothing wash immediately with soap and water If acid enters your eye immediately flood it with running cold wate...

Page 5: ... 12V 10 16VDC Input under voltage activation 12V Input under voltage protection 12V 10VDC Output voltage Output frequency Output waveform Conversion efficiency Overload protection Thermal protection USB Output Display Use of advanced microprocessor control Input under voltage protection 12V 12V 10 6VDC 120V AC 10 60Hz 1Hz Pure sine wave THD 3 90 Yes 149ºF 40ºF 65ºC 5ºC 5VDC 1A 5VDC 2 1A LED indica...

Page 6: ...n LxWxH 3 7LBs 5 3LBs 9 9LBs 11 4LBs 14 8LBs Weight 32 F 104 F 0 C 40 C Working temperature 14 F 113 F 10 C 45 C Storage temperature The offered battery cables are only for small output please choose larger battery cable for larger output Battery cables the fan starts to work when the load power is larger than 100W does not work when no load or small load The cooling fan on the product will not ru...

Page 7: ...wet or humid environment 3 The case housing of inverter will be hot when in use Keep the inverter away from materials that cannot withstand high temperature such as clothing sleeping bags carpets etc 4 This power inverter is designed for use with negative ground electrical system Don t use with positive ground electrical systems the majority of modern automobiles RVs trucks and boats are negative ...

Page 8: ...8 Disconnect the battery and inverter when it is not in use WARNING AND SAFETY CONTINUED 8 Chassis PS1001 PARTS LIST PS1001 ...

Page 9: ...PS1002 PARTS LIST PS1002 9 Chassis ...

Page 10: ...PS1003 PS1004 PS1005 PARTS LIST PS1003 PS1004 PS 1005 10 Chassis ...

Page 11: ... Pure sine inverter the area or location MUST meet the following requirements DRY Do not allow water or other fluids to drip or splash on the Pure sine inverter DO NOT MOUNT THE INVERTER IN AN AREA SUBJECT TO SPLASHING WATER AND SPRAY WATER COOL Normal air temperature should be between 32 F and 104 F 0 C and 40 C the cooler the better CONTINUED ON NEXT PAGE ...

Page 12: ...ir The more clearance for ventilation around the unit the better the performance DO NOT allow the ventilation openings on the ends of the unit to become obstructed SAFETY Do not install Pure sine inverter in the same compartment as batteries or in any compartment capable of storing flammable liquids like gasoline CLOSE THE BATTERY COMPARTMENT AND THE AC SOURCE AND LOAD PANELS Avoid excessive cable...

Page 13: ...asoline powered machinery fuel tanks or joints fittings or other connections between components of the fuel system The weight of the inverter is very heavy Be sure to place the inverter on a stable surface such as the floor a table or stand Make sure the areas you place the inverter on can withstand the weight of the inverter In addition be sure to affix the product with the provided screws to kee...

Page 14: ...rcuit breaker a fused disconnect or a separate fuse and DC disconnect Do not confuse AC circuit breakers with DC circuit breakers They are not interchange able The rating of the fuse or breaker must be matched to the size of cables used in accordance with the applicable installa tion codes The breaker or disconnect and fuse should be located as close as possible to the battery in the positive cabl...

Page 15: ...ed to negative Reversing the positive and nega tive battery cables will damage the Pure sine inverter and void your warranty Operation of the inverter without a proper ground connection may result in an electrical safety hazard Chassis Ground Grounding Ground to vehicle chassis using 8 AWG wire 15 HOW TO INSTALL THE DC CIRCUIT BREAKER DC CIRCUIT BREAKER IS NOT INCLUDED ...

Page 16: ...d contact 3 Turn on the switch The green LED power indicator light should be on 4 Turn off electrical appliance and insert the electrical appliance plug to the AC output socket of the inverter Turn on the electrical appliance for use 5 Turn off the electrical appliance and inverter if you are no longer going to use them Disconnect the inverter from the battery if it will not be in use for a long p...

Page 17: ...e power indicator on the inverter and remote control box should be on this will avoid interference 4 Turn off electrical appliance and insert the electrical appliance plug to the AC output socket of the inverter Turn on the appliance for use 5 The inverter s cooling fan will start running when the case temperature reaches about 100 F 6 When the inverter is not in use turn the inverter off by press...

Page 18: ...ation formula of operating time is battery capacity AH x battery output voltage V load power W For example Battery specification 12V 200Ah load power is 300W then the operating time is 200 x 12 300 8 hours BATTERY OPERATING TIME This unit uses the latest in soft start technology The output voltage gradually increases to the normal value from low value after the inverter is turned on It can reduce ...

Page 19: ... for most electrical appliances including linear and switching in electronic equipments transformers motor etc Compared with modified sine wave inverters the power factor and power utilization of electric fans refrigerators and other inductive loads can be improved by using pure sine wave inverters The noise during appliance operation can be effec tively reduced too 19 OUTPUT VOLTAGE WAVEFORM ...

Page 20: ...er will automatically shut down when the input DC voltage is higher than 16V The buzzer will whistle continuously and the switch indicator light will turn on If this happens turn off the inverter and adjust the input voltage to the allowed range 4 Overload protection The inverter will automatically shut down when the load power is higher than the rated power The buzzer will whistle continuously Tu...

Page 21: ...ing it after the temperature returns back to normal Meanwhile find out what factors are causing the inverter to overheat Such factors may be poor ventilation ambient temperature vent load power etc 21 FUNCTIONS CONTINUED ...

Page 22: ...it is in the allowable range of the input voltage Over temperature 1 The switch is off 2 The battery lead is not connectedl 1 Turn on the power switch 2 Check the joint and make sure it s well connected Cut off the load and keep it cool naturally for 10 to 30 minutes Restart it after it returns to normal temperature The load power is too large and reduce the total load power to the range of rated ...

Page 23: ...r then test again 1 Load power is too large or the actual power of the appliance exceeds nominal power 2 The starting power is larger than rated power such as motor Reduce a load power or open the appliance first then open the inverter the inverter internal soft start circuit to buffer start the appliances When using with TV or audio static on screen or static noise or no audio Disturbance If the ...

Page 24: ... be liable for loss of use or any other incidental consequential or indirect costs expenses or damages There are no express warranties except as listed above This warranty gives you specific legal rights and you may have other rights which vary from state to state Should this product require service or replacement at our option while under warranty CALL 1 844 539 7991 for RETURN INSTRUCTIONS Be su...

Page 25: ......

Page 26: ......

Page 27: ......