Page 09
CONTROL PANEL FEATURES
NOTE:
Total power drawn from all outlets must not exceed the nameplate rating.
1
3 4
5
6
7
8
11 10
9
2
1. Low Idle Switch:
Low idle switch minimizes fuel
consumption and noise by adjusting the engine speed
to the minimum required for the current load.
2. Overload Indicator LED (Red):
Illuminates when the
generator is overloaded which means the generator’s
wattage / amperage capacity has been exceeded by
connected electrical devices or by a power surge.
When this occurs, the Output Ready Indicator LED will
go off. The engine will continue to run, but the red
Overload Indicator LED will stay on, and power will no
longer be supplied to connected electrical devices.
To rest the generator:
Remove all applied loads and stop the engine. Review
for any faulty or shorted connections.
Start the generator and reconnect electrical devices
sequentially, allowing the generator to stabilize after
each device is connected. Make sure the total wattage
of connected electric devices are not exceeding
recommended rated output power.
3. Output Ready Indicator LED (Green):
Illuminates
when the generator is operating normally and indicates
the generator is producing electrical power at the
receptacles.
4. Oil Warning Indicator LED (Red):
Illuminates when the
engine oil level falls below the safe operating level and
the generator will automatically shut off the engine. The
engine will not start until the proper amount of oil is in
the crankcase.
5. Circuit Breaker (DC):
Protects the generator
against electrical overloads.
6. 12V DC, Outlet (Automotive):
Provides 12
volt DC power up to 8.3 amps.
7. Starting Dial Switch:
Used to start and stop the
generator.
8. Parallel Operation Outlets:
These outlets are used
for connecting two AIPOWER inverter generators
for parallel operation. Do not connect or disconnect
parallel cables while the generator is running to avoid
damage.
9. 120V AC, 30A Locking (NEMA L5-30R):
This outlet
can supply electrical power for operation of 120 Volt
output up to 30 amps.
10. Ground Terminal:
The ground terminal is used to
ground the generator.
11. 120V AC, 20A, Single Phase, 60 Hz Outlet
(NEMA 5-20R):
Outlet is capable of carrying
a maximum of 20 Amp.
12. Recoil Starter:
Pull the recoil starter to manually start
the engine.
12
Summary of Contents for SUA2000i
Page 26: ...Page 24 PARTS DIAGRAM PARTS DIAGRAM AND PARTS LIST SUA2000i ...
Page 31: ......
Page 32: ......
Page 33: ......
Page 34: ...Fontana CA 92337 USA Phone 1 855 888 3598 support a ipower com www a ipower com ...
Page 36: ...Fontana CA 92337 USA Phone 1 855 888 3598 support a ipower com www a ipower com ...
Page 64: ...Página 26 DIAGRAMA DE PIEZAS DIAGRAMA DE PIEZAS Y LISTA DE PIEZAS SUA2000i ...
Page 69: ......
Page 70: ...Fontana CA 92337 EE UU Teléfono 1 855 888 3598 support a ipower com www a ipower com ...
Page 72: ...Fontana CA 92337 EE UU Teléfono 1 855 888 3598 support a ipower com www a ipower com ...
Page 99: ...Page 25 SCHÉMA DES PIÈCES SCHÉMA DES PIÈCES ET LISTE DES PIÈCES SUA2000i ...
Page 104: ......
Page 105: ......
Page 106: ...Fontana CA 92337 USA Téléphone 1 855 888 3598 support a ipower com www a ipower com ...
Page 108: ...Fontana CA 92337 USA Téléphone 1 855 888 3598 support a ipower com www a ipower com ...