Admiral 38C Scrubber PB# 4100055UM Rev.* 08/10
PowerBoss, Inc. Copyright 2010
Page 71
Maintenance and Service
5.5.1
Filling the solution tank
Fill the solution tank (Fig. 25/4) with fresh
water and cleaning agent before starting
with the work, also refer to Section 3.1.4.
1. Park the machine on a level floor area.
2. Open the tank cap (Fig. 25/2) and lock
in place.
3. Fill the solution tank to the maximum
mark.
5.5.2
Emptying the solution tank
If the vehicle is to be left unused for a
longer period, the solution tank should be
emptied.
1. Park the vehicle so that the draining
hose can be positioned over a drain in
the floor.
2. Open the left and right rear doors
3. Detach the solution draining hose (Fig.
25/8) and lower it slowly.
4. Unscrew the cap (Fig. 25/7) to open it.
The quantity drained can be regulated
by turning the cap and pivoting the cap
open fully, if necessary.
5. When the solution tank has been com-
pletely emptied, screw the cap shut
again and attach the draining hose
again.
6. Close the left and right rear doors.
When disposing of the waste
water containing the cleaning
agent, observe all applicable
legal regulations.
5.5.3
Cleaning the draining hose cap
• The cap (Fig. 25/7) at the end of the
draining hose (Fig. 25/8) should be
cleaned at regular intervals.
• Lubricate the O-ring lightly, if neces-
sary.
5.5.4
Cleaning the filter in the
solution feed
The solution feed is equipped with a filter
(Fig. 25/5) which must be cleaned dirt
appears on the container. This is located
on the left-hand side of the vehicle at the
height of the brushes behind the side
panel.
1. Pivot the right-hand side panel up.
2. Close the ball cock (Fig. 25/6) to
prevent solution being supplied from
the tank.
3. Unscrew the container by hand and
pull the sieve insert out downwards.
4. Clean both parts with water and reas-