PowerBoss, Inc. Copyright 2010
Admiral 38C Scrubber PB# 4100055UM Rev.* 08/10
Page 74
Maintenance and Service
8. After finishing cleaning the tank, close
the flap and push the run-off plate back
in place.
9. Unhook the waste water draining hose
(Fig. 26/6), lower it slowly and open the
cap (Fig. 26/5).
10. Run fresh water in the recovery tank
through the open tank neck using a
water hose (output pressure approx. 5
to 6 bar) and, in doing so, also flushing
the draining hose (see above).
11. Screw the cap shut again and hook the
draining hose back in place.
12. Close the left and right rear doors.
The cleaning flap must not be
used to drain off waste water.
5.6.3
Cleaning the draining hose cap
• Clean the draining hose cap on a daily
basis.
• Lubricate the O-ring lightly, if neces-
sary.
5.6.4
Cleaning the air intake filter
The filter sieve (Fig. 28/1) is located in the
recovery tank above the maximum water
level on the suction pipe. The accumu-
lation of dirt in the filter sieve must be
checked daily and cleaned as necessary:
Fig 28
1. Pull the filter sieve from the suction
pipe and clean with water.
Remove the filter sieve complete-
ly to clean it.
During cleaning and operation,
pay attention that no water and
no particles of dirt get into the
suction pipe and into the suction
turbines.
2. Dry the filter sieve after cleaning. Do
not replace when dripping wet!
5.6.5
Cleaning the openings to the
solution tank
The openings between the recovery and
solution tank (Fig. 28/2) serve for ventila-
tion between the two tanks. They must be
checked regularly for accumulations of dirt
and cleaned as necessary.