SHUTDOWN AND STORAGE
NOTE:
NEVER stop the air compressor by unplugging it from the power outlet as this may
result in damage to the compressor.
1. Turn the switch to the OFF position
2. Disconnect the power cord from the power outlet. Disconnect the power cord from the
power outlet by grabbing the plug (not the cord).
3. Turn the pressure regulator knob fully counterclockwise to close airflow from air outlet
port. Check the outlet pressure gauge to ensure that it reads 0 PSI.
4. Remove the air hose and any air accessories.
5. Drain moisture from the air tank by slowly opening the air tank drain valve by turning
clockwise. Tilt tank to remove all moisture. Once all the moisture has drained out, close
the fitting securely.
6. Allow the compressor to cool down.
7. Wipe the air compressor clean and store it in a clean, dry, and non-freezing location.
MAINTENANCE AND CLEANING
Disconnect AIR COMPRESSOR from power source and
bleed off all air pressure before attempting any maintenance or repair.
WHEN PERFORMING ANY MAINTENANCE OR SERVICE:
• The air compressor must be turned off.
• Disconnect compressor from the power source.
• Open tank drain to bleed off all air pressure before attempting any maintenance or repair.
• Allow compressor to fully cool before attempting any maintenance or repair.
Check the air compressor frequently for any visible problems and follow maintenance proce-
dures each time the compressor is used.
All air compressors contain maintenance parts that require periodic
replacement. These used parts, including air filters may contain regulated substances that
must be disposed of in accordance with local, state, and federal laws and regulations.
1. Slowly open tank drain valve to release pressure from the system and drain moisture from
the air tank. Tilt tank to remove all moisture. Once all the moisture has drained out, close
tank drain valve securely.
2. Wipe the compressor clean.