4.3 UPS Control

 

Control panel functions 

Function Description 

Display 

Function Description 

LED Display 

 

Line Mode(Green) 

UPS is operating with Main power 

 

AVR Boost (Yellow) 

Correcting under-voltage condition. 

Output power remain normal

 

 

Battery Mode(Yellow) 

UPS operating with Battery power 

 

AVR Buck(Yellow) 

Correcting over-voltage condition. 

Output power remain normal 

 

Battery Fault(Red) 

Battery fault or overload occurred 

Battery Fault: steady light 

Overload: rapid flash   

 

Overload(Red) 

Load exceeds UPS capacity 

 

Battery Level Bar 

Indicating battery capacity and status 

Output Voltage 

Displaying UPS output voltage

 

Button Display 

 

ON/OFF/TEST/Silence Button 

The master button for UPS control, refer to Button Operation

 

Button operation 

Cold Start function 

When the main power is disconnected from UPS, it is capable of starting with battery power for users’ 

needs. Simply start the UPS as the instruction below. 

“On/Off/Test/Silence” button 

Turn on the UPS 

 

Switch on the Load 

 

Press the "ON" button until a single "beep" alarm disappeared or the LED display turns on. 

Shut Down the UPS

 

 

Switch off the Load 

 

Press the "OFF" button for 3 seconds during Line/Battery-mode. 

 

(If  applicable)  To  avoid  electrical  hazards,  please  turn  off  the  internal/external  input  breaker.  Then, 

turn off any external battery breaker and wait till all fans completely shut down. 

Test 

Press once to start self-test function during Line-Mode 

Silence 

Press once to enable/disable alarm buzzer during Battery-Mode 

Green mode 

The  Green  mode  feature  will  enable  UPS  no-Load  or  light-load  shutdown  to  maintain  power 

consumption  and  battery  life.  During  battery  mode,  the  UPS  will  shut  down  approximately  4  min  with  no 

load/light load operating. 

Green mode can also be enabled or disabled via monitoring software. 

Green Mode Enable: Turn on UPS normally. Green mode activates in default.

 

Green  Mode  Disable:  When  turning  on  UPS,  please  keep  holding  the  “ON”  button  until  a  double  “beep” 

occurred. 

 

4.4 UPS Configuration 

UPS Manual test 

Manual  tests  for  UPS  or  battery  can  be  conducted  from  the  UPS  configuration  as  well  and  are 

functional even when the UPS is not charging the battery. 

Simple test

: It’s recommended to conduct a simple simulation test when 

1. The first use of UPS. 

2. Adding new loads. 

3. 6 months’ regular check-up. 

Switch on the UPS and wait for the power indicator to light up, then unplug UPS to simulate the main 

power failure. 

Manual Battery Test:  Press the “test” button  once. UPS  will  automatically conduct a  self-test.  Please 

note that the UPS will briefly switch to battery mode. 

 

Summary of Contents for IMD-1025A

Page 1: ...ne Interactive 1025VA 3000VA IMD 1025A IMD 1025AP IMP 1025A IMP 1025AP IMD 1200A IMD 1200AP IMP 1200A IMP 1200AP IMD 1500A IMD 1500AP IMP 1500A IMP 1500AP IMD 2000A IMD 2000AP IMP 2000A IMP 2000AP USE...

Page 2: ...greater distance between the receiver and the equipment Ensure that your Equipment connects to an outlet on a separate circuit Contact a technician experienced with radio and TV or the dealer for tec...

Page 3: ...ceable parts inside Please refer all service to qualified service technicians CAUTION DO NOT dispose UPS and its batteries to fire the battery may explode CAUTION DO NOT attempt to open or mutilate th...

Page 4: ...ne Interactive UPS it is capable of providing clean and stable power to your critical system While the UPS regulates and filters power fluctuation it also keeps the battery charged for any emergency A...

Page 5: ...during Line Battery mode If applicable To avoid electrical hazards please turn off the internal external input breaker Then turn off any external battery breaker and wait till all fans completely shu...

Page 6: ...C to 25 C Protect the equipment from wet or damp areas and moist air To maintain the vitality of the batteries please recharges the UPS at least 8 hours every six months 6 3 Operation CAUTION Ensure t...

Page 7: ...situation feel free to contact for technical assistance PROBLEM POSSIBLE CAUSE Solutions UPS can t operate switching on No lights on no warning sound Power source mistake or low battery power Check th...

Page 8: ...Beep every 2 seconds Low Battery Beep every 0 5 second Environment Operating Humidity 0 90 RH at 0 40 C Non condensing Audible Noise Less than 40 dB IMD Series are same specification with IMP Series...

Reviews: