APP-B Technical Specifications 

Model  1025A/AP 

1200A/AP 

1500A/AP 

2000A/AP 

3000A/AP 

Configuration 

Capacity (VA/ Watts) 

1025VA/615W  1200VA/720W  1500VA/900W  2000VA/1200W  3000VA/1800W 

Form 

Tower Type 

Input 

Voltage 

100

 / 110 / 120 VAC or 220 / 230 / 240 VAC 

Input Voltage Range 

75 - 150 or 165 - 300 VAC 

Input Frequency Range 

50 Hz / 60 Hz (Auto Sensing) 

Output 

Waveform 

Simulated Sine Wave 

Voltage 

100

 / 110 / 120 VAC or 220 / 230 / 240 VAC 

Frequency 

50 Hz / 60 Hz ± 0.5 Hz   

Transfer Time 

2 - 4 ms (Typical) 

Protection 

Full Protection 

Overload, Surge, Short Circuit 

Tele Communication 

RJ11 / RJ45 : AP model 

Battery 

Type & Quantity 

12V 7.2Ahx2 

12V 

8.5

Ahx2 

12V 9Ahx3 

Typical Recharge Time 

6-8 hr to 90% 

Management & Communication 

Indicator 

LED Control Panel : IMP model / LCD Control Panel : IMD model 

Communication Port 

USB B type : AP model 

Physical 

Dimensions (WxDxH) (mm) 

130 x 382 x 200 

130 x 440 x 200 

Weight (kgs) 

13.5 

13.5 

16 

16.6 

22 

Shipping Dimensions (mm) 

253 x 488 x 321 

253 x 556 x 321 

Shipping Weight (kgs) 

15.5 

15.5 

18 

18.6 

24 

Alarm 

Overload / Fault 

Continuous Beeping   

Battery Mode 

Beep every 2 seconds 

Low Battery 

Beep every 0.5 second 

Environment 

Operating Humidity 

  0-90 % RH at 0-40°C (Non-condensing) 

Audible Noise 

Less than 40 dB 

* IMD Series are same specification with IMP Series, but in Digital Indicator. 

* Specifications are subject to change without further notice. 

* Specifications are for reference; actual information should be based on the real product. 

French Safety Instruction 

INSTRUCTIONS DE SÉCURITÉS IMPORTANTES CONSERVER 

CES INSTRUCTIONS 

Le présent manuel contient des instructions importantes qui devraient être suivies durant 

l’installation et l’entretien de l’UPS et de la batterie. 

Ces appareils sont conçus pour être installés à l’intérieur, dans un endroit à température controlee et à 

environnement non conducteur. 

Toute intervention sur les batteries devra être effectuée ou surveillée par un personnel qui connaît les 

batteries et qui prend les précautions requises. 

Interdire à tout personnel non autorisé de toucher aux batteries. 

ATTENTION 

- Afin de réduire les risques d'incendie, ne raccordez qu'à un circuit muni d'une 

protection de surintensité du circuit de dérivation maximum de 20 ampères conformément au 

Code Électrique National (National Electrical Code) des États-Unis, ANSI/NFPA 70. 

La protection de surintensité de sortie ainsi que le sectionneur doivent être fournis par des tiers. 

Summary of Contents for IMD-1025A

Page 1: ...ne Interactive 1025VA 3000VA IMD 1025A IMD 1025AP IMP 1025A IMP 1025AP IMD 1200A IMD 1200AP IMP 1200A IMP 1200AP IMD 1500A IMD 1500AP IMP 1500A IMP 1500AP IMD 2000A IMD 2000AP IMP 2000A IMP 2000AP USE...

Page 2: ...greater distance between the receiver and the equipment Ensure that your Equipment connects to an outlet on a separate circuit Contact a technician experienced with radio and TV or the dealer for tec...

Page 3: ...ceable parts inside Please refer all service to qualified service technicians CAUTION DO NOT dispose UPS and its batteries to fire the battery may explode CAUTION DO NOT attempt to open or mutilate th...

Page 4: ...ne Interactive UPS it is capable of providing clean and stable power to your critical system While the UPS regulates and filters power fluctuation it also keeps the battery charged for any emergency A...

Page 5: ...during Line Battery mode If applicable To avoid electrical hazards please turn off the internal external input breaker Then turn off any external battery breaker and wait till all fans completely shu...

Page 6: ...C to 25 C Protect the equipment from wet or damp areas and moist air To maintain the vitality of the batteries please recharges the UPS at least 8 hours every six months 6 3 Operation CAUTION Ensure t...

Page 7: ...situation feel free to contact for technical assistance PROBLEM POSSIBLE CAUSE Solutions UPS can t operate switching on No lights on no warning sound Power source mistake or low battery power Check th...

Page 8: ...Beep every 2 seconds Low Battery Beep every 0 5 second Environment Operating Humidity 0 90 RH at 0 40 C Non condensing Audible Noise Less than 40 dB IMD Series are same specification with IMP Series...