PD-3006/12
Power over LAN Solutions
6
Cat. No.: 06-6831-056
1.2
Power Cord
In the event that the power cord is replaced, the replacement must meet local
requirements.
U.S.A. and
Canada
* The cord must be UL-approved or CSA certified.
* The minimum specification for the flexible cord is:
- No. 18 AWG
- Type SV or SJ
- Three-conductor.
* The cord set must have a rated current capacity of at least
10 A.
* The attachment plug must be an earth-grounding type with a
NEMA 5-15P (15 A, 125 V) or NEMA 6-15P (15 A, 250 V)
configuration.
Denmark
* The supply plug must comply with section 107-2-D1,
standard DK2-1a or DK2-5a.
Switzerland
* The supply plug must comply with SEV/ASE 1011.
* The appliance coupler (connecting to the Midspan and not to the wall
plug) must have a configuration for mating with an EN60320/IEC320
appliance inlet.
* The power socket outlet must be near the Midspan and be easily
accessible.
You can only remove power from the unit by disconnecting
the power cord from the outlet.
* This unit operates under SELV (Safety Extra Low Voltage) conditions
according to EN60950/IEC 950. The conditions are only maintained if the
equipment to which it is connected also operates under SELV conditions.
* France and Peru only: This unit cannot be powered from IT supplies. If
your supplies are of IT type, this unit must be powered by 230 V (2P+T),
via an isolation transformer with a ratio of 1:1 and with the secondary
connection point labeled Neutral, connected directly to ground.
* U.K. only: The Power over LAN Midspan is covered by General
Approval, NS/G/12345/J/100003, for indirect connection to a public
telecommunications system.