Document Number: 06-1210-056 

Release 1.2 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Covered under US Patent 6,473,608. 

Other Patents pending. 

 
Visit our web site at: www.powerdsine.com 
 
For technical support, call: +972-9-7755123 
In the USA:  +631-756-4680 or 1-877-4-802-3AF 
Email: customer.care@powerdsine.com 
 

Summary of Contents for PD-6506

Page 1: ...P Po ow we er rD Ds si in ne e 6 65 50 00 0 S Se er ri ie es s P PD D 6 65 50 06 6 P PD D 6 65 51 12 2 P PD D 6 65 52 24 4 User Guide ...

Page 2: ...that the Midspan is designed for indoor use only 2005 PowerDsine Ltd All rights reserved This document is subject to change without notice Acknowledgements Power over Ethernet is a trademark of PowerDsine Ltd All other products or trademarks are property of their respective owners The product s described by this manual is are a licensed product of PowerDsine Notice The information contained herein...

Page 3: ... Indicators 9 2 4 Connectors 11 3 INSTALLING THE POWER OVER ETHERNET MIDSPAN 12 3 1 Background Information 12 3 2 Rack Mounting Brackets 13 3 3 General Hazards 13 3 5 Connecting Power Cables 14 3 6 Powering up 14 4 TROUBLESHOOTING 15 4 1 Preliminary Steps 15 4 2 Troubleshooting Guide 15 5 TECHNICAL SPECIFICATIONS 17 5 1 Physical Specifications 17 5 2 Environmental Specifications 17 5 3 Electrical ...

Page 4: ...er feet User Guide Power cord Before proceeding record the unit s serial number below for future reference The serial number can be found on the information label at the rear of the Power over Ethernet Midspan Serial Number Electrical Compatibility Approvals The Powerdsine 6500 complies with the following standards FCC Part 15 Class B with FTP cabling Class A with UTP cabling EN 55022 CISPR 22 Cla...

Page 5: ...er no larger than 15 A for 120 VAC U S 10 A for 230 VAC international is used Do not work on the system connect or disconnect cables during periods of lightning activity A voltage mismatch can cause equipment damage and may pose a fire hazard If the voltage indicated on the label is different from the power outlet voltage do not connect the Power over Ethernet Midspan to this outlet For shelf moun...

Page 6: ...under SELV conditions U S A and Canada The cord must be UL approved or CSA certified The minimum specification for the flexible cord is No 18 AWG Type SV or SJ Three conductor The cord set must have a rated current capacity of at least 10 A The attachment plug must be an earth grounding type with a NEMA 5 15P 15 A 125 V or NEMA 6 15P 15 A 250 V configuration Denmark The supply plug must comply wit...

Page 7: ... Ethernet infrastructure Eliminates the need for AC outlets local UPS AC DC adapters near PDs Remote Management using Web control and or SNMPv3 Highest level of Network Security Safe solution that protects network infrastructure Standards compliant 2 1 Power Management When establishing a network the total power required by the PDs may exceed the total power available from the Midspan The built in...

Page 8: ...2 2 2 Data Power Output Ports The Midspan has 6 12 or 24 x 10 100Base T Data Power Out ports located on the front panel Figure 2 2 These ports are configured in a non crossover manner straight wired and are designed to carry Ethernet data over the standard 2 wire pairs pins 1 2 and 3 6 and DC power over the spare pairs pins 4 5 and 7 8 Each output port corresponds to an opposite input port located...

Page 9: ...color indicator green per port provides port status Green indicates that the terminal unit PD has been identified as Power over Ethernet Enabled is active and receives power Blinking green indicates that the port does not supply power and is inactive Refer to Table 2 2 for additional information Note Due to the standard detection process performed on each PoE port power will not be delivered LED i...

Page 10: ...t on port output lines Green Active load is plugged in and complies with normal load conditions Continuous nominal DC voltage is present on the spare pairs Green blinks at a 1 sec rate Overload or short circuit Power to the port is disconnected No DC voltage is present on port output lines Green blinks at a 0 5 sec rate Valid load Total aggregated power exceeds pre defined power budget 400w by def...

Page 11: ...rity and 1 stop bit Pin connections for this connector are Pin 2 is Receive RXD Pin 3 is Transmit TXD Pin 5 is Ground Pins 1 and 6 are shorted DC 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 RJ IN RJ OUT Ethernet Switch PD RJ 45 RJ 45 Data Data Data Data Midspan Channel Power Bus Data Data Data DC Data DC DC Figure 2 3 Connecting to the Midspan Each data port is configured as sh...

Page 12: ...Midspan is connected in series with an Ethernet switch hub The data outputs from the switch are connected to the Midspan The Midspan delivers power over the spare twisted pairs pins 7 8 and pins 4 5 of the Category 5 cabling without degrading the quality of data Most installations require the Midspan to be rack mounted as described below Figure 3 1 Typical Installation ...

Page 13: ...nt compatible with the manufacturer s maximum rated ambient temperature Tmra b Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised c Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading d Circu...

Page 14: ...Connecting Power Cables When using AC source to power the Midspan plug in the provided power cord at the rear AC connector 3 6 Powering up The Power over Ethernet Midspan has no on off switch To apply power to the Midspan or remove power from the Midspan insert or remove the power cable from the receptacle AC on the rear panel of the unit With power applied the Midspan powers up and the internal f...

Page 15: ... Troubleshooting Steps Symptom Corrective Steps Midspan does not power up 1 Establish that the power cord is viable 2 Verify that the voltage at the power inlet is between 100 and 240 Vac 3 Remove and re apply power to the device and check the indicators during power up sequence A port indicator is not lit and the corresponding PD does not operate 1 The Midspan did not detect a PD and therefore th...

Page 16: ...g a standard UTP FTP Category 5 straight non crossover cabling with all four pairs Verify that the link is 100 m or less 4 Try to re connect the same PD to a different port on the same midspan or to a different unit if it works there is probably a faulty port or faulty RJ 45 connection Is it safe to keep the Midspan running while a port indicator is orange This is a safe condition The orange indic...

Page 17: ...11lb 5 2 Environmental Specifications Temperature Operating 0 to 40 C 32 to 104 F Storage 20 to 70 C 4 to 158 F Humidity 10 to 90 non condensing 5 3 Electrical Specifications Parameter PD 6506 6512 6524 AC M PD 6524 AC M F AC Input Voltage 90 to 264 VAC at 47 63 Hz Input Current 115 VAC 4 A max 5 5 A max Total Output Power 200W max 400W max Output Power per Port 15 4 W not to exceed Total Output P...

Page 18: ...n ports supporting hard resets of remote terminals such as WLAN Access Points and VoIP Phones PowerView Pro allows monitoring and controlling at Network and Element levels as shown in Figure 6 1 For further details refer to PowerDsine s PowerView Web Manager User Guide Figure 6 1 Management Deployment The PowerView Pro provides a number of unique features for Midspan management Remote Web Manageme...

Page 19: ...P Po ow we er rD Ds si in ne e 6 65 50 00 0 S Se er ri ie es s PowerDsine 19 The Power over Ethernet Pioneers ...

Page 20: ... Release 1 2 Covered under US Patent 6 473 608 Other Patents pending Visit our web site at www powerdsine com For technical support call 972 9 7755123 In the USA 631 756 4680 or 1 877 4 802 3AF Email customer care powerdsine com ...