20
iii.
Use a grease gun to enlarge the grease fitting and supply the power volume of grease
as indicated below table. Grease all three pin crank bearings from the grease fittings.
Grease delivery (Pin crank bearings)
1st time
2nd time
1st time
2nd time
1st time
2nd time
4 times
4 times
5 times
5 times
7 times
7 times
SLAE03E
SLAE05E
SLAE05EHP
CAUTION
Use only Powerex genuine grease. Pump grease gun before using feeding (this eliminates
air from the grease passage of the extension adaptor).
Part Number: IP616200AJ (complete kit), IP600000AV (grease tube)
Notes
: Each pump of the grease gun equals 0.65 g of grease.
Grease fitting
Summary of Contents for SLAE03E
Page 1: ...Scroll Compressor Service and Maintenance Manual ...
Page 4: ...4 INTAKE AIR FILTER REPLACEMENT every 2 500 HOURS MAINTENANCE 1 Remove the Filter Cover ...
Page 6: ...6 3 Reassemble the Filter Cover ...
Page 8: ...8 2 Clean FS fins with a blow gun ...
Page 9: ...9 3 Reassemble the FS cover ...
Page 11: ...11 2 Blow off dirt and dust ...
Page 12: ...12 FAN DUCT CLEANING 5 000 HOURS MAINTENANCE Wipe out dirt and dust ...
Page 17: ...17 v Put the removed Plastic Dust Cap back ...
Page 18: ...18 2 PIN CRANK BEARINGS i Remove the Fan Duct 2 Remove these three bolts ...
Page 24: ...24 2 REPLACEMENT i Remove the fan duct 2 Remove these bolts ...
Page 27: ...27 iv Remove dust from both OS and FS plates with clean cloth or air ...
Page 30: ...30 vii Insert LP Tip Seal all the way and cut excessive material ...
Page 31: ...31 viii Repeat the same procedure for FS Tip Seal set ...
Page 34: ...34 PARTS LIST ...