3
MAINTENANCE SCHEDULE
Item
Action needed
Page
500
2,500
5,000
10,000
15,000
Remarks
Intake air filter
Replace
4
●
▲
(Every 2,500 hours or less)
Part #91348550
Cooling fins
Clean
7
●
(Every 2,500 hours or less)
Blower fan
Clean
10
●
●
●
Fan duct
Clean
12
●
●
●
Bearings
Regrease
13
●
Service Center Only
Tip Seal set
Replace
22
▲
●:
Inspect
▲:
Replace
NOTES:
1. Inspect and perform maintenance periodically according to maintenance schedule.
2. The maintenance schedule relates to the normal operating conditions. If the circumstances and load condition are adverse, shorten the
cycle time and do maintenance accordingly.
3. *The tension of the V-belt should be adjusted during the initial stage and inspected every 2,500 hours afterwards. Proper belt tension for 3
HP unit is 7 lbs./0.16" deflection; for 5 HP units, 7 lbs./0.19" deflection.
4. Air end life is as below.
Regular pressure model: 20,000 hours, High pressure model: 15,000 hours
Operating Hours
(Every 5,000 hours for high pressure model)
(Every 5,000 hours for high pressure model)
Summary of Contents for SLAE03E
Page 1: ...Scroll Compressor Service and Maintenance Manual ...
Page 4: ...4 INTAKE AIR FILTER REPLACEMENT every 2 500 HOURS MAINTENANCE 1 Remove the Filter Cover ...
Page 6: ...6 3 Reassemble the Filter Cover ...
Page 8: ...8 2 Clean FS fins with a blow gun ...
Page 9: ...9 3 Reassemble the FS cover ...
Page 11: ...11 2 Blow off dirt and dust ...
Page 12: ...12 FAN DUCT CLEANING 5 000 HOURS MAINTENANCE Wipe out dirt and dust ...
Page 17: ...17 v Put the removed Plastic Dust Cap back ...
Page 18: ...18 2 PIN CRANK BEARINGS i Remove the Fan Duct 2 Remove these three bolts ...
Page 24: ...24 2 REPLACEMENT i Remove the fan duct 2 Remove these bolts ...
Page 27: ...27 iv Remove dust from both OS and FS plates with clean cloth or air ...
Page 30: ...30 vii Insert LP Tip Seal all the way and cut excessive material ...
Page 31: ...31 viii Repeat the same procedure for FS Tip Seal set ...
Page 34: ...34 PARTS LIST ...