3. Product Overview 

Front View:   

 

VI 1000 LED 

VI 1500 / 2000 LED 

 
Back View: 

   

VI 1000 LED 

VI 1500 / 2000 LED 

 

4. 

Installation and Initial Startup

 

NOTE: 

Before installation, please inspect the unit. Be sure that nothing inside the package 

is damaged.   
 

1) Placement & Storage Conditions 

Install the UPS in a protected area that is free of excessive dust and has adequate air flow. 
Please place the UPS away from other units at least 20 cm to avoid interference. Do NOT 
operate the UPS where the temperature exceeds 0-40° C and the humidity is over 0-90 % 
RH.  

         

 

2) Connect to Utility and Charge 

Plug in the AC input cord to the wall outlet. For the best 
results, we suggest charging the battery at least 6 hours 
before initial use. The unit charges its battery while 
connecting to the utility. 
 

3) Connect the Loads 

Plug in the loads to output receptacles on the rear panel of the UPS. Simply turn on the 
power switch of UPS unit, and devices connected to the UPS will be protected by UPS unit. 
 

 

 
4) Connect Modem/Phone/Network for Surge Protection (Only for the model 
with RJ-45)   

Connect a single modem/phone line into surge-protected “IN” outlet on the back panel of 
the UPS unit. Connect from “OUT” outlet to the computer with phone line cable.   
 

5) Connect USB Cable

 

To monitor the UPS status, such as unattended UPS shutdown and start-up, by using 
bundled software, please connect the UPS and PC with USB cable included.   
 

 

 
6) Turn On/Off the Unit 

Turn on the UPS unit by pressing the power switch. Turn off the UPS unit by pressing again 
the power switch.    

 

5. Audible alarm from the UPS   

 

When UPS switches from AC mode to Battery Mode to back up power supply: 
sounding every 10 seconds

 

 

When battery is low: sounding every second

 

 

When UPS is overloaded:    sounding every 0.5 second

 

 

When battery is faulty: sounding every 2 seconds

 

Other fault: Continuously sounding 

 

6. Software Installation on your PC 

1) Use the bundled CD and follow the on-screen instructions to install the software View 
_Power. 
2) After the software is successfully installed, the communication with UPS has been 
established and an orange icon will appear in the system tray.     
3) Double-click the icon to use the monitor (as above).         
You can schedule UPS shutdown/start-up and monitor UPS status through PC. 
Detail instructions please refer to the e-manual in the software.   
 

 

Do not attach a power strip or surge suppressor to the UPS.

 

 

NEVER 

connect a 

laser printer

 or 

scanner

 

to the UPS unit, 

because in-rush current 

generated by motor’s devices 

may cause the 

damage of the unit.

X

 Power switch                   

Y

 AC mode indicator: green 

lighting 

Z

 Battery mode indicator: yellow 

lighting 

[

 Fault indicator: red lighting 

\

 UPS status indicator: 

AC mode: green lighting 
Battery mode: green flashing 

]

 AC mode: load level indicator 

   Battery mode: battery capacity 

indicator 

X

 Output receptacles                         

Y

 AC input

Z

 Circuit breaker 

[

 Modem/phone/Network surge 

protection 

\

 USB port 

 

GB 

GB 