background image

 

 

Safety Instructions 

• Connect the POWERGRIP Console directly to a stationary grounded power outlet. Do not connect with an 
extension cord, power distribution unit, UPS, protection device or voltage stabilizer unless approved by the 
manufacturer. 

• Do not expose the unit to moisture. Use indoors only. 

• In case of a device malfunction only use an authorized POWERGRIP service facility. 

• A vibration damper is fitted inside. Do not shake, turn over the unit or put it on its side. 

• To ensure proper filtration and protection, all powered devices in your AV system need to be connected to 
a POWERGRIP console. 

• Any kind of incoming antenna cables must be grounded with the connector supplied. 

• Connect with correct Live/Neutral alignment only (13). 

• This power console can withstand significant power surges, but it’s recommended to disconnect the 
console's power plug from the mains during a thunderstorm. 
 
• In case of a direct connection to the mains with a power line RCC (Residual Current Circuit) ‘Circuit Breaker’ 
an over Current Protection for 16A / 25A must be used. 

 

 

What is in the box: 

 

YG-3 Clean Power Console 

 

Power cord IEC-C19-Schuko 2m 

 

3RU Rack mounts 

 

Antenna grounding cord 

 

Blank plate cover, to be used in case of direct power cord connection 

 

Useful knowledge: 

 

Trigger input got optical isolation and support pass through mode. It will help you avoid ground loop 
caused by trigger connection between processor and amplifier. 

 

IFTTT service can help you to connect different IoT devices. 

 

NOTE: Manufactures can change device specification without notification. 
 

 

 

Summary of Contents for YG-3

Page 1: ...Clean Power Console POWERGRIP YG 3 Clean Power and Smart Protection for your A V system ...

Page 2: ...s POWERGRIP www powergrip com Thank you for using this online manual instead of printing it This helps to save our planet and enables us to edit the manual from time to time to make sure it is up to date complete and easy to understand Please make sure you are using the manual for the respective product version The product version can be found in the device menu information section This manual is ...

Page 3: ...pplied Connect with correct Live Neutral alignment only 13 This power console can withstand significant power surges but it s recommended to disconnect the console s power plug from the mains during a thunderstorm In case of a direct connection to the mains with a power line RCC Residual Current Circuit Circuit Breaker an over Current Protection for 16A 25A must be used What is in the box YG 3 Cle...

Page 4: ... Long press to enter Menu To disable demonstration mode enter Menu Display Choose style 3 Assignable touch sensors the led indicator shows assigned function status While in menu use left and right to move the cursor and the middle to enter change 4 Display Note For English language menu press English the centre button during the initial boot up screen ...

Page 5: ...inal optional extra Contact POWERGRIP dealer to purchase 9 Trigger input for control by 3rd party devices Can operate as RS232 input see www powergrip com for more information Output is to control 3rd party devices 10 Socket group number 11 Ground terminal Must be connected if several power consoles are used together 12 Socket with entire console Power On Off Auto sensor Can be used to turn on off...

Page 6: ...er DC filter Ground indicator Turn off ground indicator This may be required in TT functional earthing power systems if the neutral to ground voltage is high Trigger option list Power ON Activation at power on Sens btn1 Activation with sensor 1 enumeration from left to right Sens btn2 Activation with sensor 2 enumeration from left to right Sens btn3 Activation with sensor 3 enumeration from left t...

Page 7: ...t background Arrow2 Analog arrow meter with color background Oscil 1 Oscilloscope meter without background Oscil 2 Oscilloscope meter without background Demo Demo mode for shop Auto style change Indication Amount of display information OFF Display turned off Min Voltage only Full All available information Color Indication color Bg color Color of sensor buttons in off function state OFF brightness ...

Page 8: ...details Trigger option list Power ON Activation at power on Sens btn1 Activation with sensor 1 enumeration from left to right Sens btn2 Activation with sensor 2 enumeration from left to right Sens btn3 Activation with sensor 3 enumeration from left to right Sens btn4 Activation with sensor 4 enumeration from left to right Sens btn5 Activation with sensor 5 enumeration from left to right Trigger Ac...

Page 9: ...tn3 Link to sensor button 3 enumeration from left to right Sens btn4 Link to sensor button 4 enumeration from left to right Sens btn5 Link to sensor button 5 enumeration from left to right Sequencer Link to Main Sequencer button top button not linked Sequencer Group 2 6 on Group turn on delay sequencer will not trigger this group This group control can also be set in commutation menu Trigger on Tr...

Page 10: ...nsole turn on will be unstable set it one step less 2 Turn connected device into standby mode Set off threshold a little more than current consumption value On threshold must higher than the off threshold RS232 address RS232 address for control system RS232 terminal terminal for RS232 test Ethernet terminal terminal for Ethernet test Ethernet ECO turn off Ethernet power if all groups are off Avail...

Page 11: ...cer turn off sequence 3 Voltage flicker voltage pick fluctuation for one minute High flicker can cause connected devices fault even with normal voltage 5V or higher high stress to connected devices May reduce life of the connected devices 11V or more there is a risk of damage to the connected devices It is recommended to call professional electrician for help 4 Mains frequency indicate the load of...

Page 12: ...7 DC filter state 8 DC over mains value indicates a mains voltage unbalance DC forces power transformers to make more noise Usually after value of 50mV transformers starts to make noise By default the console turns on the DC filter if the value is more than 60mV during 20seconds The settings can be changed in the filtering section on the menu 9 Wi Fi indicator Appears during connection or in case ...

Page 13: ...is selected as trigger the filter state will depend on the state of that option Hi Fi High Current DC filter By default the filter is in automatic mode and will be applied if the DC value is more then 60мВ during a 20 second period Settings can be changed in the menu Constant states are available as well In case an amplifier with a switch mode power supply is connected the DC filter must be turned...

Page 14: ...s the existence of the ground and the proper connection phase In case ground exists and the YG 3 power plug is connected with the wrong phase operation of the unit will be blocked If grounding doesn t exist or the power line does not comply with TN standard this function is not available In this case you need to connect YG 3 as shown on diagram 13 by using a phase detecting tool Antenna grounding ...

Page 15: ...filtering DC value 1 8V 14 Maximum on off delay 60Sec 15 Operation temperature range 10 40 C 16 Weight of the console 7 6Kg 17 Maximum weight of device placed on top of YG 3 10Kg 18 Alignment horizontal only 19 Height with feet 156 5mm 20 Depth 280mm without connectors 21 Width 440mm front panel 43cm 19 22 Box size 56 x 41 5 x 28cm 23 Weight in the box 10 5Kg Warranty A 1 year warranty covers all ...

Page 16: ... mains to devices Differential mode RED Filter option in off state Yellow Filter option in on state Dumper is off Green Filter option in on state Dumper is on General filter plot Filtering from devices to mains Differential mode common mode ...

Page 17: ...t sensor Socket group 1 Relay group 2 Socket group 2 Socket group 3 Relay group 3 DC filter bypass relay Parallel configurable filter High current Hi Fi Filter Relay group 6 Relay group 5 Additional parallel filter Relay group 4 Socket group 6 Socket group 5 Socket group 4 Additional parallel filter Additional parallel filter Block diagram ...

Page 18: ...www powergrip com ...