Assembly Instructions
35
Step 7
Install the Valve Plate to the Beam
Assembly.
Use 3/8” x 1” Bolts and 3/8” Flange Nut.
Step 8
Install the Hose Barb Elbow to the Control
Valve port marked “Out”. Orient Hose Barb
Down as Shown.
Attach the Control Valve to the Valve Plate.
Use 1/4” x 1-3/4” Bolts and 1/4” Flange
Nuts
Valve plate
3/8” x 1” bolts
3/8” flange nuts
Beam assembly
1/4” nuts
1/4” x 1-3/4” bolts
Valve plate
Hose barb elbow
Control valve
Reducer fitting
High Pressure Elbow
Pump hose
Control valve
Pump
Step 9
Attach the Reducer Fitting and the High
Pressure Elbow to the Control Valve port
marked “IN”. Orient the High Pressure
Elbow as shown.
Attach Pump Hose to the Pump, use Teflon
Tape on threads into Pump.
Attach the loose end to the High Pressure
Elbow, Teflon Tape is not needed.
Summary of Contents for M11571E
Page 2: ...Hazard Signal Word Definitions 2...
Page 24: ...Parts Breakdown Exploded View Rev E 24...
Page 32: ...Assembly Instructions 32...