background image

PH4000Ri/E Owner’s Manual

13

5. 

Pre-operation check

• 

Be sure to check the generator on a level surface with the engine stopped.

5.1.  Check the Engine Oil Level

• 

Do not use non-detergent oil or 2-stroke engine oil. It will void the warranty and will shorten the 

engine's service life.

• 

Use a high-detergent, premium quality 4-stroke engine oil, certified to meet or exceed U.S. 

automobile manufacturer's requirements for API Service Classification SG/SF. Synthetic oil is 

approved for use in POWERHOUSE

®

 generators, and is recommended for operating the generator in 

temperatures below 32° F.

• 

Change the oil in a new engine within the first 4 to 6 hours of operation to clean manufacturing debris 

and contamination.

• 

Use SAE 10W-30 or 15W-30 viscosity oil unless operating at ambient temperatures below 

32° F (0° C). For temperatures below 32° F, use SAE 0W-30 or 0W-40 viscosity oil. Refer to 

Operating at Extreme Temperatures

 for more information.

• 

Synthetic oil is approved for use in POWERHOUSE

®

 generators generally, and is recommended 

when operating the generator in temperatures below 32° F. You can use synthetic oil the first time you 

fill the oil well of your generator, and you can use it for subsequent oil changes.

1. 

Loosen the oil access cover screw and remove the cover.

2. 

Remove the dipstick, wipe it with a clean rag and reinsert it into the filler neck, screwing it down completely.

3. 

Remove the dipstick again and check the oil level.

4. 

If the oil level is at or below the lower level on the dipstick, refill with the recommended oil up to the top of the upper 

level marking. Do not overfill.

5. 

Reinsert the dipstick and be sure to screw it down until it is tight.

6. 

Reinstall the oil access cover and tighten the screw securely.

• 

Running the engine with insufficient oil can cause serious engine damage.

• 

The Low oil alarm system will automatically stop the engine before the oil level falls below a safe 

limit. However, to avoid the inconvenience of an unexpected shutdown, it is still advisable to visually 

inspect the oil level regularly.

Engine oil capacity: 33.8 fl oz. (2.11 pt) / 1.0 L

WARNING

!

CAUTION

!

NOTE

!

WARNING

!

OVERLOAD

RUN

LOW OIL

OVERLOAD

RESET

STOP

12 V DC 8.3 A

ON

OFF

REMOTE 

CONTROL

ECONOMY 

SWITCH

START

ON

OFF

HOURS      1/1 0

BATTERY CHAR

GE

ON

OFF

ON

OFF

120 V AC RECEPTACLE

S

120 V AC CIRCUIT BREA

KERS

20 A

30 A

20 A

30 A

Oil

reservoir

Summary of Contents for PH4000Ri/E

Page 1: ...POWERHOUSE PH4000Ri E Electronic Fuel Injected Digital Inverter Generator Owner s Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE USING...

Page 2: ...door and connect the quick connect cable to the battery wiring harness Refer to Connecting The Battery for more information 3 Replace the maintenance door 4 Connect an external battery charger such as...

Page 3: ...three seconds to allow the fuel pressure to build and the throttle valve to close iv Push the start button on the remote and hold until the engine has started or for a maximum of 10 seconds Release a...

Page 4: ...Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequ...

Page 5: ...rranty powerhouse products com or send a fax to 1 855 242 8922 Failure to properly follow these precautions can result in property damage serious injury or DEATH Read all labels and the owner s manual...

Page 6: ...plication 23 6 11 Generator Overload 24 6 12 Overspeed Protection 24 6 13 DC Application 25 6 13 1 Charging External Batteries 25 6 13 2 Powering 12V DC devices 26 6 13 3 Back charging the generator b...

Page 7: ...des increased efficiency over carbureted fuel systems In a carbureted fuel system the fuel and air are mixed in a carburetor that relies on a mechanical choke system controlling the rate of air intake...

Page 8: ...il tight For safety reasons it is better to shut the generator down before moving it You should also unplug all cords connected to the generator to prevent a tripping hazard and or damage to the cords...

Page 9: ...amage and or severe personal injury or death may result Never connect this generator to an automatic transfer switch ATS Severe damage to the generator will occur Never connect this generator to an au...

Page 10: ...wner s Manual 10 4 Component identification 4 1 PH4000Ri E Generator Control panel Gas gauge Gas cap Starter grip Engine oil access door Pneumatic tire Maintenance door Stabilizing rubber feet Telesco...

Page 11: ...OTTANT SYSTEM FLOATING RESEAU FLOTTANT Digital display Ignition switch Fault code button 120 V circuit breakers 120 V duplex receptacle Stop button red Ground terminal 120 V locking receptacle Low oil...

Page 12: ...enerator toward the muffler grill close to the bottom 2 On the back of this owner s manual You can also find the BCN number on the foil label on the shipping carton Please record this information belo...

Page 13: ...es below 32 F You can use synthetic oil the first time you fill the oil well of your generator and you can use it for subsequent oil changes 1 Loosen the oil access cover screw and remove the cover 2...

Page 14: ...operly and securely Be careful not to spill fuel when refueling Spilled fuel or fuel vapor may ignite If any fuel is spilled make sure the area is dry before starting the engine Avoid repeated or prol...

Page 15: ...to connect the battery before you begin using the generator Due to the nature of lead acid batteries it may be necessary to charge the battery before using the generator the first time or after long t...

Page 16: ...reported by a sensor These shutdowns may occur when you are not present When the generator engine shuts off there will still be a drain on the battery due to the display the ECU and the stepper motor...

Page 17: ...of how you start the unit If the battery charge is just high enough to run the fuel pump and the ECU the generator can be started by recoil but not by the ignition key or remote You must either charg...

Page 18: ...using the remote function 1 Move the remote selector switch on the control panel to the ON position 2 Push the start button on the remote twice and hold while the engine cranks 2 3 times without start...

Page 19: ...erator is 0 to 113 F 18 to 45 C Although the generator can operate at 0 F 18 C it will be necessary to use a lower viscosity engine oil such as SAE 0W 40 Synthetic oil is recommended for temperatures...

Page 20: ...receptacle Do not connect the generator to a household circuit This could cause damage to the generator or to electrical appliances in the house Do not modify or use the generator for purposes other...

Page 21: ...lay will not illuminate unless the generator is started It is normal for the run time indicator to have 1 2 hours on the meter from the factory for testing and quality assurance inspections The digita...

Page 22: ...ection of this manual When the Low Oil indicator blinks repeatedly press the fault code button on the top right of the digital display The display will cycle through the fault codes in the Wattage P d...

Page 23: ...is illuminated and returning data 3 Confirm that the appliance to be used is switched off before plugging into the control panel 4 Plug the appliance into the control panel Be sure that all appliance...

Page 24: ...t exceed that of the generator 6 12 Overspeed Protection This generator has been designed to prevent the engine from overspeed revving Overspeed revving occurs when a generator s on board monitoring s...

Page 25: ...cord to the positive battery terminal Do not reverse the charging cables or serious damage to the generator and or battery may occur Physical injury may also occur Do not attempt to start an automobi...

Page 26: ...re are no special considerations for switches to be on or off for the battery to charge though if the generator is not running the remote switch should be in the OFF position The ECU and fuel pump req...

Page 27: ...codes section of this manual for more information 6 15 Stopping the engine To stop the engine in an emergency 1 Push the STOP button on the control panel This will stop the unit with or without the i...

Page 28: ...as started and is performing normally It is also important to follow the air conditioner manufacturer s instructions for starting and restarting for proper operation Some air conditioner manufacturers...

Page 29: ...standards regarding the emission control system Tune up specifications are provided in the Specifications section and a description of the emission control system may be found in the appendix to this...

Page 30: ...o compare the emission performance of different engines The lower the air index the better the engine emission performance The description of durability is helpful for the user to learn the engine emi...

Page 31: ...ine Check Every 2 years Replace as necessary 3 Battery Clean Charge Charge monthly during long term storage Check terminals for corrosion monthly clean as needed Expected battery life is 2 years but c...

Page 32: ...dipstick 6 Reinstall the oil access cover and tighten the screw securely Recommended oil is SAE 10W 30 or 15W 30 when ambient temperature is above 32 F 0 C SAE 0W 30 or 0W 40 is recommended if operati...

Page 33: ...id engine wear may result 1 Loosen the cover screws and remove the maintenance door 2 Remove the cartridge retaining screws Remove the cartridge and check the element Clean or replace the element if n...

Page 34: ...y carefully bending the side electrode 9 Install the spark plug carefully by hand to avoid cross threading 10 After a new spark plug has been seated by hand it should be tightened 1 2 turn with a wren...

Page 35: ...ff the grill This will not cause an issue unless you drop the arrester or the clamp or screws behind the grill Taking the grill off or leaving it on is a matter of your convenience but the procedure b...

Page 36: ...nerator while it is on or in a vehicle If you must transport the generator in an enclosed vehicle drain all fuel from the generator 8 2 Short term storage of the Generator During short term storage th...

Page 37: ...ignition switch to the OFF position 4 Siphon the fuel from the tank 5 Change the engine oil 6 Remove the spark plug and pour about a tablespoon of clean engine oil into the cylinder 7 Crank the engin...

Page 38: ...rator and retry Is the key fob battery drained Replace the key fob battery Is the remote switch turned off Turn on the remote switch Is the battery fuse missing or burned out Is the battery dead Check...

Page 39: ...on switch on Turn the ignition switch to the START position Is there enough oil in the engine Add the recommended oil Is there a spark from the spark plug Warning Be sure there is no spilled fuel arou...

Page 40: ...or equipment Check for power using a meter or a known good appliance Did pressing the overload reset button cause the appliance to operate Replace the electrical appliance or equipment Take the elect...

Page 41: ...F7RTC Starting system Remote Electric Recoil Fuel Automotive unleaded gasoline Lube oil synthetic or conventional SAE 10W 30 15W 30 0W 30 0W 40 below 32 F Oil Capacity 33 8 fl oz 1 0 L Fuel tank capa...

Page 42: ...r or replace any part or unit at its option Coast Distribution may request defective parts to be returned Anything replaced under warranty becomes the property of Coast Distribution To Obtain Warranty...

Page 43: ...ystem is warranted for two years If any emissions related part on your engine is defective the part will be repaired or replaced by Coast Distribution System Inc Owner s Warranty Responsibilities As t...

Page 44: ...injector system Engine speed control system ECU Intake manifold Engine control module Evaporative Control System Fuel tank Fuel cap Fuel strainer Fuel injector Fuel pump Fuel lines Carbon canister in...

Page 45: ...k cap indicator and hoses are specially designed and constructed to not allow fuel vapors to permeate and be released to the atmosphere 2 A carbon activated canister collects gasoline vapors from the...

Page 46: ...E AND DAMAGE THE CHARGER LOCATE THE CHARGER AS FAR AWAY FROM THE BATTERY AS DC CABLES PERMIT k DO NOT OPERATE CHARGER IN A CLOSED IN AREA OR RESTRICT VENTILATION IN ANY WAY l CONNECT AND DISCONNECT DC...

Page 47: ...HEN CONNECT THE NEGATIVE BLACK CHARGER CLIP TO FREE END OF CABLE v DO NOT FACE BATTERY WHEN MAKING FINAL CONNECTION vi CONNECT CHARGER AC SUPPLY CORD TO ELECTRICAL OUTLET AND vii WHEN DISCONNECTING CH...

Page 48: ...7930 S W Burns Way Unit C Wilsonville OR 97070 www powerhouse products com This manual version applies to BCNs equal to or greater than 140915415155001 PH4000Ri E Owner s Manual Revision 2014 08 27 BC...

Reviews: