11
CAUTION
It is very important to note that there are several factors that need to be considered in
determining the maximum working load for every application. These factors include but are
not limited to the following:
• Applied Load
• Operating Speed
• Acceleration/Deceleration
• Cable Length
• Shock Load
• Abrasion
• Corrosion
• Quantity, quality, design, and location of drums and sheaves
• Inspection Facilities
• Safety Risks to life and property
During coiling or winding of the cable onto the spool, make sure that tightness of the layers
is consistent all throughout the coiling or winding. Do not coil a tight layer of cable over a
loose layer. This may cause the outer tight layers to exert additional force between the layers
and cause a jam. When unspooling the cable, put tension on the brake to make sure the
spool speed is lower than the cable speed.
Always store, maintain and handle the products properly before and after each use.
Do not use
linked or knotted cable
. Regularly inspect your product and its parts.