The following instructions refer to the wiring diagrams on: 

 
 

 
 

 

Verify that the dumbwaiter has a.c. power. 
A. 

Check the circuit breaker to see if it has been tripped and reset breaker. 

B. 

Check the overload 

“Reset” button, on the side of the controller box, to see if it has popped 

out and reset it, if necessary, by pushing it back in. 

(for “Reset” location on P-100 & 200 see Page 12) 
(for “Reset” location on single phase P-300 & 500 see Page 13) 
(the “Reset” on three phase P-300 & 500 is inside the controller)

 

 

Check for 24 volts a.c. in control box.

 

A. 

Use a volt meter to test the low voltage side of the transformer.  Connecting volt meter leads 
to the brown and yellow wires should show at least 24V a.c. 

B. 

Check lighted relays 1 & 2 to see if both relays are lit. 

I.  If relay 2 is lit and relay 1 is not, go on to step 3. 

II.  If both are out, check the 2 amp fuse mounted inside the control box on the side.  It is best 

to remove the fuse and check for burn marks.  Replace if blown. 

 

Test the safety circuit.

 

A. 

On terminal bar, for 2 stop machines, short out terminals 6 and 7.  For 3 and 4 stop machines, 
short out terminals 1 and 2. 

I.  If relay 1 clicks, the safety circuit is not complete, go on to step 4. 

II.  If relay 1 is lit and does not click, check the connections to the push buttons. 

 

Manually moving dumbwaiter car. 
A. 

Verify all doors are closed and dumbwaiter car is not lower than the bottom floor opening or 
higher than the top floor opening. 

I.  If dumbwaiter car is not vertically out of alignment and still does not function, please call 

Powerlift Dumbwaiters, Inc. 

II.  If dumbwaiter car is vertically out of alignment, use the 

“UP” contactor to adjust the car up 

or use the 

“DOWN” contactor to adjust the car down. 

Contactor operation 

  With 2 stop machines, the contactor will stay in when pressed and the dumbwaiter car will 

automatically go to the nearest floor when working properly.  If the contactor does not stay in, 
there is a low voltage problem.  Please call Powerlift Dumbwaiters, Inc. 

  With 3 & 4 stop machines, the contactor will never stay in.  If power is lost while the 

dumbwaiter car is between stops, the contactors will work like a momentary contact switch, 
and may be used to bump the car up or down to the nearest floor.  Once the car is aligned with 
an opening, the pc board will be reset and the dumbwaiter should function properly. 

 

Troubleshooting

 

All Models 

 

USING THE CONTACTORS TO MOVE THE DUMBWAITER CAR BYPASSES THE ENTIRE 

SAFETY CIRCUIT.  HOLDING THE CONTACTOR IN COULD DAMAGE THE DUMBWAITER 

AND/OR CAUSE SERIOUS BODILY INJURY, LOSS OF LIMB, OR DEATH!

 

 WARNING 

Page 15 -- for 2-stop single phase machines 

Page 16 -- for 2-stop three phase machines 

Page 19 -- for 3-stop single phase machines 

Page 20 -- for 3-stop three phase machines 

Page 21 -- for 4-stop single phase machines 

Page 22 -- for 4-stop three phase machines 

Summary of Contents for MJ-500

Page 1: ...injury or death 2018 08 08 12 07 17 www dumbwaiters com All persons who use this dumbwaiter bear the responsibility for the proper and safe use of this product Misuse deliberate or otherwise voids al...

Page 2: ...www dumbwaiters com 1 800 409 5438 Page 2...

Page 3: ...t hesitate to contact us on our toll free number in the USA or 1 530 333 1953 for international customers We offer free technical support for your dumbwaiter and our staff will be happy to help you Th...

Page 4: ...sting Chain Tension motor on the top Lubricating Brake Solenoid P 100 P 200 Lubricating Brake Solenoid P 300 MJ 500 Troubleshooting Wiring Diagram 2 stop single phase Wiring Diagram 2 stop three phase...

Page 5: ...fire is present 8 DO NOT REMOVE BYPASS OR ALTER any switches controls and or restraining devices These are mandated by national and local codes and safety regulations Any tampering will void your warr...

Page 6: ...door lock catch 4 Hoistway door 5 Dumbwaiter car 6 Data plate 7 Call send push buttons 8 Motor controller 9 Power supply 10 Brake solenoid cover 11 Motor access door panel Identifying Parts of the Dum...

Page 7: ...solenoid cover 5 Motor access door panel 6 Call send push buttons 7 RDI door interlock 8 RDI door interlock catch 9 Hole to access emergency override switch 10 Data plate 11 Dumbwaiter car 12 Hoistwa...

Page 8: ...pletely closed the dumbwaiter will not operate 5 Press the call send button that corresponds with the floor you want to send the dumbwaiter car to 6 Once the dumbwaiter car stops at the specified floo...

Page 9: ...hs Lubricating the idler pulley Place a few drops of lightweight oil on the shaft next to the pulley on each side see Figure 5 Lubricating the pillow block assembly Using a grease gun apply a few pump...

Page 10: ...se pliers to hold the chain from twisting and tighten lock nut up to adjustment nut securely see Figure 8 NOTE Do not overtighten the chain If the chain slaps during operation of the dumbwaiter the ch...

Page 11: ...U OLQN SODWH DQG SLQ DVVHPEO 3XVK WKH PDVWHU OLQN SODWH DQG SLQ DVVHPEO WKURXJK ERWK HQGV RI WKH UROOHU FKDLQ QVWDOO WKH PDVWHU OLQN SODWH DQG SLQ DVVHPEO VR WKH JURRYHG HQGV RI WKH SLQV IDFH RXWZDUG...

Page 12: ...master link plate and pin assembly through both ends of the roller chain Install the master link plate and pin assembly so the grooved ends of the pins face outward Install the master link plate The m...

Page 13: ...ar down until the top of the car is lined up with the bottom of the top hoistway door see Figures 10 11 13 6 Using two 9 16 wrenches 15 16 for MJ 500 model back lock nut off and then tighten down adju...

Page 14: ...BRICATE HERE AND ON OPPOSITE SIDE WITH LIGHT LUBRICANT BRAKE DRUM BRAKE PAD BRAKE SHOE SOLENOID COVER SCREWS SOLENOID REMOVE SOLENOID COVER FOR EASY ACCESS TO BRAKE SOLENOID Maintenance Lubricating Br...

Page 15: ...e Lubricating Brake Solenoid P 300 MJ 500 YOU MUST ACCESS THE BRAKE SOLENOID THROUGH THE MOTOR ACCESS PANEL DOOR FAILURE TO DO SO COULD DAMAGE THE DUMBWAITER AND OR CAUSE SERIOUS BODILY INJURY LOSS OF...

Page 16: ...ng dumbwaiter car A Verify all doors are closed and dumbwaiter car is not lower than the bottom floor opening or higher than the top floor opening I If dumbwaiter car is not vertically out of alignmen...

Page 17: ...www dumbwaiters com 1 800 409 5438 Page 15 Troubleshooting Controller Wiring Diagram 2 Stop Single Phase...

Page 18: ...www dumbwaiters com 1 800 409 5438 Page 16 Troubleshooting Controller Wiring Diagram 2 Stop Three Phase...

Page 19: ...www dumbwaiters com 1 800 409 5438 Page 17 Troubleshooting Dynamic Brake Wiring Diagram Single Phase...

Page 20: ...www dumbwaiters com 1 800 409 5438 Page 18 Troubleshooting Dynamic Brake Wiring Diagram Three Phase...

Page 21: ...www dumbwaiters com 1 800 409 5438 Page 19 Troubleshooting Controller Wiring Diagram 3 Stop Single Phase...

Page 22: ...www dumbwaiters com 1 800 409 5438 Page 20 Troubleshooting Controller Wiring Diagram 3 Stop Three Phase...

Page 23: ...www dumbwaiters com 1 800 409 5438 Page 21 Troubleshooting Controller Wiring Diagram 4 Stop Single Phase...

Page 24: ...www dumbwaiters com 1 800 409 5438 Page 22 Troubleshooting Controller Wiring Diagram 4 Stop Three Phase...

Page 25: ...www dumbwaiters com 1 800 409 5438 Page 23 From all of us at Powerlift Dumbwaiters Inc Thank you for your business May God bless you and your family...

Reviews: