background image

Note: Adjustment can be made in (4) locations to get desired closed position, as 

described below. Always start with Option “a”.

a.  Move the gate bracket to left or right of the 36 inch starting position.

b.  Change length of connecting rod assembly.

c.  Relocate control arm extension on control arm to a different hole pattern then 

start position. See Figure 6.

d.  Move connecting rod bolt in gate bracket to a different hole. See Figure 8

7. 

Move control arm to its open position as shown in Figure 9

Note: Arm and connecting rod should 

almost double over each other. This is 

important for smooth operation and 

longevity of the operator.

Note: Open position of gate may be 

adjusted slightly with limit switch 

adjustment, but when finished, open 

position of control arm assembly should 

be as close as possible to that shown in 

Figure 9. If mechanical adjustments are 

made to achieve desired open position 

of gate, repeat 

Steps 6 & 7

, since this will 

affect the closed position. 

8.  When the desired open and closed g

ate position have been achieved, place gate in the 

fully closed position a

nd remove control arm extension from control arm. See Figure 6.

9.  Remove control arm from operator drive shaft and insert drive key. See Figure 6.

10.  Replace control arm on operator drive shaft with drive key and secure with 3/8 inch bolt. 

See Figure 6.

11.  Replace control arm extension on control arm and secure with hand knobs as shown in 

Figure 6.

GATE

OPERATOR

CONNECTING 

ROD ASSEMBLY

CONTROL ARM 

ASSEMBLY

FIGURE 9

12.  By turning the internal drive pulley by hand, move the control arm to somewhere in  

its normal drive segment.

13.  Control arm extension may now be attached to control arm as in Figure 6.

Note: If operator was ordered as a right or left hand unit from the factory, the control 

arm position will be somewhere in its normal travel segment and the limit switches will 

be set at an approximate open and close position. Final adjustments will be made later 

after power is connected.

 

If the hand of the operator is to be changed in the field as described in the following 

section than before the control arm extension is replaced as in

 Step #11

, proceed to 

Step #12

.

Summary of Contents for rsw

Page 1: ...GTH X 10 1 2 WIDTH 2 O D PIPE BY OTHERS INSTALLATION AND OWNER S MANUAL MODEL RSW Swing Gate Operator UL 325 and UL 991 Listed READ THIS MANUAL CAREFULLY BEFORE INSTALLATION OR USE SAVE THESE INSTRUCT...

Page 2: ...14 Electrical Connections 15 Left Hand Right Hand Conversion 16 Connection of a 3 Button Station 16 Limit Adjustment 17 Master Slave Installation 18 Timer to Close 18 Accessory Connections Connection...

Page 3: ...provide an overview of the importance of safe design installation and use Warnings are identified with the symbol This symbol will identify some of the conditions that can result in serious injury or...

Page 4: ...board must learn what the monitored device is To have the board learn the monitored device perform the following steps 1 With the power off hold both the open and close limit simultaneously 2 Power up...

Page 5: ...family units hotel garages retail store or other building servicing the general public CLASS III INDUSTRIAL LIMITED ACCESS VEHICULAR GATE OPERATOR A vehicular gate operator or system intended for use...

Page 6: ...owing diagram Figure 1 5 Design the gate system so a person cannot reach over under around or through the gate to operate any controls Never place controls on the gate operator itself THIS GATE SYSTEM...

Page 7: ...g the correct type of safety equipment consult the factory 6 Review the operation of the unit and become familiar with the manual operation procedure and safety features of the system 7 You must insta...

Page 8: ...in sight of the gate opening AFTER INSTALLATION You are responsible for ensuring that the end user understands the basic operations and safety systems of the unit INCLUDING THE MANUAL OPERATION PROCED...

Page 9: ...gate 3 DO NOT allow children to play near your gate or to operate the gate 4 DO NOT operate your gate system unless you can see it when the gate moves 5 Be sure a pushbutton or key switch has been ins...

Page 10: ...ng a rigid object or when a non contact sensor is activated If these functions are observed to operate improperly discontinue use and have it serviced immediately 11 You are responsible for ensuring t...

Page 11: ...e sure you know how to properly use this feature To disengage operator follow the procedure in Figure 2 FIGURE 3 LEFT HAND INSTALLATION FENCE FENCE OPERATOR OPERATOR HINGE HINGE GATE GATE RIGHT HAND I...

Page 12: ...r to operator installation Note Distance between mounting posts and relative location to gate is very important Operator must be installed perpendicular to the fence GATE HINGE GROUND LEVEL 17 3 8 21...

Page 13: ...nd connecting rod must be straight in line FIGURE 7 FIGURE 8 NOTE TO DISCONNECT OPERATOR FOR MANUAL OPERATION REMOVE HANDKNOBS AND SEPARATE CONTROL ARM EXTENSION FROM CONTROL ARM HAND KNOBS FOR MANUAL...

Page 14: ...esired open and closed gate position have been achieved place gate in the fully closed position and remove control arm extension from control arm See Figure 6 9 Remove control arm from operator drive...

Page 15: ...ed in accordance with N E C and local codes NOTE In order to properly run and check the operator at various stages during the setup procedure it is suggested that a three button control station be con...

Page 16: ...0 1 Connect a wire from the COMMON connection of the control station to Terminal 5 2 Connect a second wire from the OPEN button of the control station to Terminal 6 3 Connect a third wire from the CLO...

Page 17: ...E button and stop gate in mid travel with STOP button 5 Repeat procedure until desired open setting is obtained CLOSE LIMIT SWITCH ADJUSTMENT 1 Press CLOSE button on control station Gate should stop b...

Page 18: ...SLAVE POSITION ON MASTER POSITION OFF JUMPER JUMPER ON SLAVE SLAVE ON FIGURE 12 MASTER SLAVE 15 14 13 12 11 9 8 7 6 5 4 3 2 1 10 16 17 18 15 14 13 12 11 9 8 7 6 5 4 3 2 1 10 16 17 18 TIMER TO CLOSE OP...

Page 19: ...ght depicts the typical loop options for a Swing Gate installation 1 The Exit Loop provides a signal to open the gate when a vehicle enters the loop zone 2 The Reversing Loop protects a vehicle in the...

Page 20: ...special installations Call 1 800 243 4476 LOOP SIZE OF TURNS LOOP WIRE LENGTH FT 4 X 4 4 64 4 X 6 4 80 4 X 8 3 72 4 X 10 3 84 4 X 12 3 96 4 X 14 3 108 4 X 16 3 120 4 X 18 3 132 4 X 20 3 144 4 X 22 3 1...

Page 21: ...reful not to damage the wire insulation during installation 4 After completing the required number of loop turns twist the ends together at the rate of 6 turns per foot to form the lead in 5 Seal the...

Page 22: ...witch the gate will stop and sound a warning signal A constant pressure control will then be needed to start the gate This sensing system has sensitivity adjustments located on the printed circuit boa...

Page 23: ...ts when the gate is moving 1 Install electric edge sensors in locations shown on the right NOTE A separate pedestrian gate must be installed if there is no other entry access but the vehicular gate Ou...

Page 24: ...ON 1 Install photoelectric cell as close to FULL OPEN and FULL CLOSED position of gate as possible 2 Photocells should be installed across the gate opening and behind the gate at least 10 inches above...

Page 25: ...for proper operation by blocking the beam across the gate opening while the gate is running closed NOTE The gate should STOP AND REVERSE a short distance and then STOP 7 Test the OPEN OBSTRUCTION SEN...

Page 26: ...Notes...

Page 27: ...ar period provided that product has been registered A one year warranty applies if product has not been registered If any part is found to be defective during this period new parts will be furnished f...

Page 28: ...wer net faqs Call us toll free 1 800 243 4476 Email us PMtech VEpower net www facebook com PowerMasterOperators REV 2017 1024 Scan QR Code with your Smart phone to find us on the web WWW VEPOWER NET M...

Reviews: