21
BL
Y
BK
WH
Not Used
NOTE: TWIST LEADS APPROX.
6 TURNS PER FOOT
REVERSING LOOP CONNECTION
TO
DRIVEWAY
LOOP
BR
GY
GR
V
OR
R
P
BK
BL
Y
WH
V
OR
Not Used
TO
DRIVEWAY
LOOP
NOTE: TWIST LEADS APPROX.
6 TURNS PER FOOT
EXIT LOOP CONNECTION
R
BR
GY
GR
P
3. Leaving enough wire for the lead-in, insert the specified number of turns of wire in the
cut grooves (See chart).
CAUTION: Be careful not to damage the wire insulation during installation.
4. After completing the required number of loop turns, twist the ends together at the rate
of 6 turns per foot to form the lead-in.
5. Seal the lead-in wire in the conduit to prevent moisture seepage into the conduit.
6. Fill over the loop wires in the groove with a recommended loop sealant. Contact your
distributor for available sealants.
7. Mount the loop detector in the operator and connect the wire loop.
8. Connect loop detector to the control board as shown in the following diagrams:
A
7 8 9 10
B
A
2 3 4 5
B