FRAME PREPARATION FOR
FRAME PLATE
DOOR PREPARATION FOR
BODY & DOOR PLATE
3
4
NB To ensure correct operation of
closer there must be a 3mm / 1/8” gap
between the two fixing plates when
the door is in the closed position.
These instructions are based on the
gap between door and frame being
3mm ± 1.0mm
•
Drill 4 x 28mm / 1 1/8”
Ø holes x 30mm /
1 5/16” deep to accept frame plate assembly
as indicated on template
•
Drill 2 x 28mm / 1 1/8” Ø holes x 5mm deep
to accept frame plate ends.
*
• Remove excess timber between drilled
holes to accommodate frame plate.
* IF USING INTUMESCENT
KIT R97-XX, REFER TO
INSTRUCTIONS WITH
KIT AS INSTALLATION
DEPTHS WILL INCREASE
•
Drill 4 x 26mm / 1 1/16”
Ø x 185mm /
7 5/16” deep holes to accept closer body as
indicated on template.
*
•
Drill 2 x 28mm / 1 1/8” Ø holes x 5mm to
accept door plate ends.
*
• Remove excess timber between drilled
holes to accept the closer body and door
plate.