background image

Important - Read before installing. 

1

Must only be installed by a 
LICENSED ELECTRICIAN to local 
wiring regulations. Failure to 
follow these instructions can 
result in serious injury or death.

This is a semiconductor 
switching device, the mains 
power MUST BE SWITCHED OFF 
before performing any wiring or 
maintenance work.

AVOID THE RISK OF ELECTRIC SHOCK

Once the product has been fastened to the wall, 
ensure the supplied screw caps are placed firmly 
into the screw mounting holes.

Screw 

mounting 

holes

Factory Reset.

Remove the cover and press the RESET
button until the Powermesh indicator flashes blue. 
Release the button and when the indicator turns 
blue, it’s ready to pair.

2

Part Number:  

PMLD, PMLDBK

Line Voltage Frequency:  

50Hz Nominal

Load Brightness Control Range:   

1% to > 95% (load dependent)

Rated Load: 

Maximum Load 1A @ 250V / 250W

Minimum Load:  

2W

Dimmable LED 
Drivers & Lamps 

Incandescent

Dimmable CFLs

Due to the variety of LED lamps / transformers / 
CFLs, the maximum load and performance will 
be specific to the product make and model.

Standard iron core & 
toroidal transformers

Electronic 
transformers

Specifications

Compatible load types

Surge protection is recommended

 at the main switchboard. Products 

that are damaged by power surges are not covered by warranty.

Powermesh products must only be connected with the 

Active and Neutral from the same RCD.

3

• Press x 1 - on /off.
• Press & hold to dim.
• Press x 2 - full brightness
• Press x 3 - timed fade to off.

Set device Min & Max 
dimming levels in 
Zimi ‘Settings’ to avoid 
flicker if necessary.

Light Dimming Button 

with mini brightness 
indicator.

Mounting screws

Reset Button

Using the Light Dimmer.

Powermesh 
Status Indicator

See overleaf for the 
meaning of each 
colour status.

Snap on cover

MAC ID

Unique product 
serial number.

Let’s get 

connected.

Light Dimmer.