background image

Let’s get 

connected.

Multi Purpose Switch.

Important - Read before installing. 

1

Megger testing may lead to low readings due to electronic components so 
disconnect all electronic devices before taking reading. Install the included 
warning sticker with circuit detail in the main electrical switch board.

Surge protection is recommended at the main switchboard. 
Products damaged by power surges are not covered by warranty.

Powermesh devices must only be connected 
with the Active and Neutral from the same RCD.

Failure to follow these 
instructions can result in 
serious injury or death.

Must only be installed by a 
LICENSED ELECTRICIAN 
to local wiring regulations.

Switch

Push button switch 
for on and off with 
LED indicator.

Mounting Screws

Included on rear
of device.

Factory Reset

Press until indicator flashes 
blue to restore factory 
settings. When the indicator 
turns blue, it’s ready to pair.

(remove cover)

Using the Multi Purpose Switch.

2

Powermesh 
Status Indicator

See overleaf for the 
meaning of each 
colour status.

Snap on cover

MAC ID

Unique product 
serial number. 

(remove cover)

Identifying the switches.

3

LO

AD 

1

LO

AD 

2

LO

AD 

3

LO

AD 

4

LO

AD 

1

LO

AD 

2

LO

AD 

3

LO

AD 

1

LO

AD 

2

LO

AD 

1

1 Button

PMMPS1 

PMMPS1BK 

2 Button

PMMPS2 

PMMPS2BK

3 Button

PMMPS3 

PMMPS3BK

4 Button

PMMPS4 

PMMPS4BK

1

1

1

4

3

2

1

2

2

3

Summary of Contents for zimi

Page 1: ... result in serious injury or death Must only be installed by a LICENSED ELECTRICIAN to local wiring regulations Switch Push button switch for on and off with LED indicator Mounting Screws Included on rear of device Factory Reset Press until indicator flashes blue to restore factory settings When the indicator turns blue it s ready to pair remove cover Using the Multi Purpose Switch 2 Powermesh Statu...

Page 2: ...3 LOAD 2 NEUTRAL ACTIVE LOAD 1 NEUTRAL LINE LOAD 1 LOAD 4 LOAD 3 LOAD 2 NEUTRAL ACTIVE Always use a Neutral wire where possible When operating without a neutral connected a small amount of power is used via LOAD 1 when switched off This may in some instances result with lights not completely turning off Dimmable loads might be fixed by increasing to at least 2 lights with a load 10W Non Dimmable load...

Page 3: ... makes multi way switching easy Buttons turn off and on together when either one is pressed Multi way switching Zimi Cloud Connect Requires Wi Fi with Internet connection Remote access anywhere Voice control hands free Energy history over time 8 Enjoy the full experience with all your Powermesh devices Want to learn more or need help support zimi life Enjoy all the features to make your life easier...

Page 4: ... with the warranty when making a claim under this warranty Failure to produce documentary proof of the date of original acquisition by the original Purchaser will result in a charge being levied for work done labour and parts supplied Likewise a charge will be made for any calls following warranty claim where no fault is found with the unit Service during the warranty period The first point of cont...