background image

REGULAR MAINTENANCE

1. Frequent, but not excessive, lubrication is required for best performance. 
Oil added through the airline connection will lubricate internal parts. An 
automatic airline oilier is recommended but oil may be added manually 
before every operation or after about 8 hours of continuous use. 

Only a few drops of oil at a time are necessary. Too much oil will collect 
inside the tool and be blown out during the exhaust cycle. ONLY USE 
PNEUMATIC TOOL OIL. Do not use detergent oil or additives, as these 
lubricants will cause accelerated wear to the seals in the tool.

7

Figure 3

2. Use a small amount of oil on all moving surfaces and pivots.

3. Dirt and water in the air supply are major causes of pneumatic tool wear

. Use a fi lter/oiler for better 

performance and longer life. The fi lter must have adequate fl ow capacity for the specifi c application.  

4. Keep tools clean for better and safer performance. Use nonfl ammable cleaning solutions only if 
necessary. CAUTION: Soaking the tool may damage O-rings and other 

tool parts. 

MAINTENANCE

WARNING!

1. Read and understand operating manual 
before using.
2. Operator and all the by-standers must wear 
ANSI approved safety glasses, ear and head 
protections.
3. Never use oxygen or other fl ammable gases. 
Only choose clean dry regulated compressed 
air below 110 PSI pressure.
4. Remove fi nger from trigger while not 
operating.
5. Never trip over the hose. Make sure all 
connections are tight.
6. Disconnect the tool from air supply before 
clearing jams, serviceing, adjusting or during 
non-operation.
7. Don’t point tool at people or animals while 
operating.

MODEL

2000F

1” - 1-1/4“  (25mm - 32mm) Length

USE 20 GAUGE L-POWERCLEATS

NAILER SAFETY LABELS

Operating Pressure

70 - 110 psi

Summary of Contents for Powernailer 2000F

Page 1: ...O MANUEL D INSTRUCTIONS ET D ENTRETIEN Read this manual before you use this Powernailer Follow all safety warnings and instructions If you are uncertain about the operation of the nailer call us direc...

Page 2: ...end of the warranty period POWERNAIL will perform all repair or replacements itself or through its authorized distributors POWERNAIL is not responsible for shipping labor or other direct or indirect...

Page 3: ...ified to assess the safe working condition of fastener driving tools Always make sure Nailer is empty of nails before connecting air hose so as to prevent any accidental discharge from occurring ONLY...

Page 4: ...e nailer will drive and set the nail at the correct angle Note Modifying or altering the nailer in anyway can potentially cause injury and may void the warranty The unique body design allows for diffe...

Page 5: ...on and set the compressors pressure regulator to the proper pressure Normal operating pressure should be adjusted between 70 110 psi based on fastener and wood being used 4 Connect the tool to the air...

Page 6: ...L GUIDE 44 and slide the channel guide out fully as shown in Figure 5 2 Place a full stick of 1 or 1 1 4 20 OPERATION continued Figure 5 Figure 6 Lock Fixed Channel Movable Channel Guide gage Powercle...

Page 7: ...ter performance and longer life The filter must have adequate flow capacity for the specific application 4 Keep tools clean for better and safer performance Use nonflammable cleaning solutions only if...

Page 8: ...3 Slide the gate plate down until it is free from the nose 6 Lift the gate plate 72 off 5 Inspect and clear any debris from the drive blade 27 and its path Reassembly 1 Install the the gate plate over...

Page 9: ...Tool skips a fastener 1 Worn bumper 22 or damaged spring 57 2 Dirt in gate 50 3 Inadequate airflow to tool 4 Worn or dry O ring 17 on piston 5 Cylinder cap seal leaking 8 1 Replace bumper or pusher sp...

Page 10: ...0F8026 27 SAFETY TRIGGER S 09 20F8027 28 E RING S 09 20F8028 29 O RING n a 30 COVER n a 31 AIR PLUG n a 32 TRIGGER VALVE ASSEMBLY n a 33 SPRING n a 34 MAIN TRIGGER n a 35 HEX HEAD BOLT S 09 20F8035 36...

Page 11: ...11 MODEL 2000F SCHEMATIC A...

Page 12: ...roper length of Powercleats to use for various thicknesses of flooring Approximate vertical penetration of the Powercleat under the hardwood floor is shown for each application This is only a guide Re...