6.1 

D

o’s 

 

The compressor must be used in a suitable environment (well ventilated with an ambient 
temperature of b5°C and +40°C) and never in places with dust, acids, vapors, 
explosive or flammable gases. 

 

Keep the work area free. When operating, the compressor must be placed on a stable 
surface. 

 

Safety goggles should be worn when using the compressor in order to protect the eyes 
against any foreign bodies lifted by the jet of air. 

 

If possible, when using air-powered accessories, wear safety clothing. 

 

Always maintain a safety distance of at least 2 meters between the compressor and the 
work area. 

 

Check for correspondence between the compressor plate data with the actual 
specifications of the electrical system. A variation of ± 10% with respect of the rated value 
is allowed. 

 

Insert the plug of the electrical cable in a socket of suitable shape, voltage and frequency 
complying with current regulations. 

 

Always use the handle to move the compressor. 

 

When using compressed air, you must know and comply with the safety precautions to be 
adopted for each type of application (inflation, airpowered tools, painting, washing with 
water-based detergents only, clinching, etc.). 

 

To avoid overheating of the electric motor, this compressor is designed for intermittent 
duty operation as indicated on the technical dataplate (for example, S3-15 means 1.5 
minutes On, 8.5 minutes OFF). In case of overheating, the thermal cutout of the motor is 
released, automatically cutting off the power when the temperature is too high due to 
excess current take-off. The motor restarts automatically when normal temperature 
conditions are restored. 

6.2 

D

on’ts 

 

Never direct the jet of air towards persons, animals or your body. 

 

Never let the compressor come into contact with water or other liquids and never direct the 
jet of liquids sprayed by tools connected to the compressor towards the compressor: as 
the appliance is live, this could cause electrocution or short-circuits. 

 

Never use the appliance with bare feet or wet hands or feet. 

 

Never leave the appliance exposed to adverse weather conditions (rain, sun, fog, snow). 

 

If this compressor is used outdoors, always remember to stow it after use in a covered or 
closed place 

 

Never use the compressor outdoors in rain or bad weather. 

 

Never allow inexpert persons to use the compressor without suitable surveillance. Keep 
animals at a distance from the work area. 

 

The compressed air produced by the compressor cannot not be used for pharmaceutical, 
food or medical purposes or to fill the air bottles of scuba divers. 

 

Do not place flammable or nylon/fabric objects close to and/or on the compressor. 

 

Do not cover the air inlets on the compressor. 

 

Do not open or tamper with any part of the compressor. Contact an authorized Service 
Center. 

7  ADDITIONAL SAFETY INSTRUCTIONS FOR BATTERIES AND 

CHARGERS 

7.1 

Batteries 

 

Never attempt to open for any reason. 

 

Do not store in locations where the temperature may exceed 40 °C. 

 

Charge only at ambient temperatures between 4 °C and 40 °C. 

Summary of Contents for POWDP7070

Page 1: ...s 6 6 2 Don ts 6 7 ADDITIONAL SAFETY INSTRUCTIONS FOR BATTERIES AND CHARGERS 6 7 1 Batteries 6 7 2 Chargers 7 8 CHARGING AND INSERTION OR REMOVAL OF BATTERY 7 8 1 Charger indications Fig 1 7 8 2 Remov...

Page 2: ...POWDP7070 EN Copyright 2020 VARO P a g e 2 www varo com 10 2 Transport 9 11 TROUBLE SHOOTING 10 12 TECHNICAL DATA 10 13 NOISE 10 14 WARRANTY 11 15 ENVIRONMENT 11 16 DECLARATION OF CONFORMITY 12...

Page 3: ...ion water 12 Battery pack not supplied 3 PACKAGE CONTENT LIST Remove all packing materials Remove remaining packaging and transit supports if existing Check the completeness of the packing content Che...

Page 4: ...earthed or grounded surfaces such as pipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is earthed or grounded Do not expose power tools to rain or wet...

Page 5: ...not allow persons unfamiliar with the power tool or these instructions to operate the power tool Power tools are dangerous in the hands of untrained users Maintain power tools Check for misalignment...

Page 6: ...FF In case of overheating the thermal cutout of the motor is released automatically cutting off the power when the temperature is too high due to excess current take off The motor restarts automatical...

Page 7: ...using a cloth Avoid skin contact In case of skin or eye contact follow the instructions below Immediately rinse with water Neutralize with a mild acid such as lemon juice or vinegar In case of eye co...

Page 8: ...ose 3 LED might show the status of the capacity level of the battery 3 LED s are lit Battery fully charged 2 LED s are lit Battery 60 charged 1 LED is lit Battery almost discharged 9 USE OF THE COMPRE...

Page 9: ...d to the compressor When two batteries are connected to the compressor the batteries will discharge alternately increasing the operating time This interaction gives the batteries enough time to cool d...

Page 10: ...by a service center 3 Check the drainage cock and replace if necessary The compressor starts pressure is shown on the pressure gauge but the tools do not start 1 The hose connections have a leak 2 A...

Page 11: ...netration intentional damage on purpose or by gross carelessness inappropriate usage use for purposes for which the device is not suitable incompetent usage e g not following the instructions given in...

Page 12: ...dification of the apparatus voids this declaration European Directives including if applicable their amendments up to the date of signature 2011 65 EU 2006 42 EC 2014 30 EU 2000 14 EC Annex VI LwA Mea...

Reviews: