POWDP7070
EN
Copyright © 2020 VARO
P a g e
|
8
www.varo.com
NOTE: If battery is hot after continuous use in the tool, allow it to cool down
to room temperature before charging. This will extend the life of your
batteries.
8.2
Removal / insertion of battery (Fig. 2)
WARNING: Before making any adjustments ensure the machine is switched
off or remove the battery pack.
▪
Hold the tool with one hand and the battery pack with the other.
▪
To install: push and slide battery pack into battery port, make sure the release latch on the
rear side of the battery snaps into place and battery is secure before beginning operation.
▪
To remove: Press the battery release latch and pull the battery pack out at the same time.
8.3
Battery capacity indicator (Fig. 3)
There are battery capacity indicators on the battery pack, you can check the capacity status of
the battery if you squeeze the button (A) Before using the machine, please press switch trigger
to check if the battery is full enough for properly working.
Those 3 LED might show the status of the capacity level of the battery:
3 LED’s are lit: Battery fully charged
2 LED’s are lit: Battery 60% charged
1 LED is lit: Battery almost discharged
9 USE OF THE COMPRESSOR
9.1
Switching ON/OFF
To switch on the equipment, set the on/off switch (8) to position 1.
To switch off the equipment, move the on/off switch (8) to position 0.
9.2
Adjusting the outlet pressure
▪
Set the control pressure at the pressure regulator (7). The current control pressure is
shown at the control pressure manometer (6).
▪
NOTE: the set control pressure must not exceed the maximum operating pressure of the
connected compressed air tools.
9.3
Setting the pressure switch
The pressure switch is set at the factory.
▪
Cut-in pressure approx. 6bar.
▪
Cut-out pressure approx.. 8bar.
As soon as the tank pressure is built up, the motor switches off
automatically.
The motor switches automatically on as soon as the tank pressure
becomes too low.
9.4
Safety valve
The safety valve (10) has been set for the highest permitted pressure of the pressure vessel. It
is prohibited to adjust the safety valve or remove its seal.
Actuate the safety valve from time to time to ensure that it works when required.