CF(M)-3K/2K-12 SUPERCOMBI USER’S GUIDE
6
1.2 Model Definition
The model format is shown below:
Example
:
In which:
No. Spec.
Values
(a)
Solar Panel MPPT
Module
M: With MPPT module
Empty: Without MPPT module
(b) Invert Power
2K: 2000W; 3K: 3000W
(c) Max. Charge Current
200: 200A/150: 150A/100: 100A
135: 135A/100: 100A/60: 60A
0: 0A(Only Inverter, not Combi)
(d) AC Outputs
D: Double Outputs. Find more in 6.1 Dual AC
Outputs.
Empty: Single Output
(e)
Actual Max. Charge
Current
If a=2K Then Empty
If a=3K Then
100: 100 Amperes
150: 150 Amperes
Empty: 200 Amperes
(f)
Country Code
A: Australia
①
Invert AC Voltage
A: 220Vac / B: 230Vac / C: 240Vac
②
Charge function
Empty: With Charge Function
N: Without Charge Function
③
ChargePro Function
C: With ChargePro Function. Find more in
6.2 ChargePro Function (Optional)
Empty: Without ChargePro Function