9 CLEANING AND MAINTENANCE
Attention !Before performing any work on the equipment, pull the power
plug.
9.1
Cleaning
▪
Keep the ventilation slots of the machine clean to prevent overheating of the engine.
▪
Regularly clean the machine housing with a soft cloth, preferably after each use.
▪
Keep the ventilation slots free from dust and dirt.
▪
If the dirt does not come off use a soft cloth moistened with soapy water.
Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.
9.2
Lubrication
From time to time, apply a drop of oil to the thread of the lock screw.
10 TECHNICAL DATA
Rated voltage
220-240V
Rated frequency
50Hz
Rated power
1300W
Rotation speed
5500min
-1
Blade diameter
190mm
Cable length
4m
Max cutting capacity 90°
65mm
Max cutting capacity 45°
48mm
Bore size
20mm
Adjustable angle
Yes
Number of teeth
40T
Blade dimensions
190 x 20mm
11 NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
99 dB(A)
Acoustic power level LwA
112 dB(A)
ATTENTION! Wear hearing protection when sound pressure is
over 85 dB(A).
aw (Vibration)
2.5 m/s²
K = 1.5 m/s²
12 SERVICE DEPARTMENT
▪
Damaged switches must be replaced by our after-sales service department.
▪
If the connecting cable (or mains plug) is damaged, it must be replaced by a particular
connecting cable which is available from our service department. Replacement of the
connecting cable must only be carried out by our service department (see last page) or by
a qualified person (qualified electrician).