background image

 

POWX1706 

EN

 

Copyright © 2021 VARO 

P a g e

 | 

2

 

www.varo.com 

12

 

DECLARATION OF CONFORMITY .............................................. 12

 

 

Summary of Contents for POWX1706

Page 1: ... 5 2 Don ts 7 6 OPERATION 8 6 1 Switching on and off 8 6 1 1 Switching the appliance on 8 6 1 2 Switching the appliance off 8 6 2 Compressed air hose with quick coupler 5 8 6 2 1 Connecting 8 6 2 2 Cutting 8 6 3 Inflation 8 6 3 1 Using the adapter 8 6 3 2 Using the valve adapter 13 9 6 3 3 Using the ball needle 12 universal adapter 11 10 6 3 4 Using the adapter set 10 6 3 5 Using with the extensio...

Page 2: ...POWX1706 EN Copyright 2021 VARO P a g e 2 www varo com 12 DECLARATION OF CONFORMITY 12 ...

Page 3: ...ter for the nozzle set 19 Extension nozzle 20 Quick connector air outlet 2 PACKAGE CONTENT LIST Remove all packing materials Remove remaining packaging and transit supports if existing Check the completeness of the packing content Check the appliance the power cord the power plug and all accessories for transportation damages Keep the packaging materials as far as possible till the end of the warr...

Page 4: ...ids gases or dust Power tools create sparks which may ignite the dust or fumes Keep children and bystanders away while operating a power tool Distractions can cause you to lose control 4 2 Electrical safety Always check that the power supply corresponds to the voltage on the rating plate Power tool plugs must match the outlet Never modify the plug in any way Do not use any adapter plugs with earth...

Page 5: ... of these devices can reduce dust related hazards 4 4 Power tool use and care Do not force the power tool Use the correct power tool for your application The correct power tool will do the job better and safer at the rate for which it was designed Do not use the power tool if the switch does not turn it on and off Any power tool that cannot be controlled with the switch is dangerous and must be re...

Page 6: ...nd personal injury Protect the hoses against kinking constriction solvents and sharp edges Ensure that the hose clamps are always tight Loose or damaged hose clamps can allow air to escape in an uncontrolled manner Replace a damaged hose immediately A faulty supply line can cause a compressed air hose to thrash about and cause personal injury Do not breath in the exhaust air directly The hose must...

Page 7: ...xcess current take off The motor restarts automatically when normal temperature conditions are restored 5 2 Don ts Never direct the jet of air towards persons animals or your body Never let the compressor come into contact with water or other liquids and never direct the jet of liquids sprayed by tools connected to the compressor towards the compressor as the appliance is live this could cause ele...

Page 8: ...15 of the period in other words 1 5 minutes During the rest of the time period cooling phase 8 5 minutes the appliance cools down again 6 2 Compressed air hose with quick coupler 5 6 2 1 Connecting Push the compressed air connector 9 into the quick coupler of the compressed air hose 5 the sleeve automatically springs forwards 6 2 2 Cutting Pull back the sleeve on the quick coupler of the compresse...

Page 9: ... socket Switch the ON OFF switch 1 to I Read the air pressure from the manometer 6 Switch the ON OFF switchto 1 O as soon as the correct or permissible air pressure has been reached Press down the lever quick coupler 9 and pull it off the valve Remove the mains plug 4 from the mains power socket 6 3 2 Using the valve adapter 13 Sclaverand valve race valve Dunlop valve bicycle valve Area of use The...

Page 10: ... Use the deflating valve adapter 15 for this purpose The two tapered universal adapters 14 11 can also be used to inflate air mattresses 6 3 5 Using with the extension nozzle 19 The extension nozzle 19 is used for cleaning blowing out of concealed spaces or hard to reach areas as well as for the cleaning of contaminated equipment The infinitely variable trigger 10 allows an exact dosage of the com...

Page 11: ...rvice centre for Powerplus tools You can always obtain more information at the number 00 32 3 292 92 90 Any transportation costs shall always be borne by the customer unless agreed otherwise in writing At the same time no claim can be made on the warranty if the damage of the device is the result of negligent maintenance or overload Definitely excluded from the warranty is damage resulting from fl...

Page 12: ...rmity with the essential requirements and other relevant provisions of the applicable European Directives based on the application of European harmonized standards Any unauthorized modification of the apparatus voids this declaration European Directives including if applicable their amendments up to the date of signature 2011 65 EU 2006 42 EC 2014 30 EU 2000 14 EC Annex VI LwA Measured 96 dB A Gua...

Reviews: