If operating a power tool in a damp location is unavoidable, use a residual current device 
(RCD) protected supply. Use of an RCD reduces the risk of electric shock. 

4.3 

Personal safety 

 

Stay alert, watch what you are doing and use common sense when operating a power 
tool. Do not use a power tool while you are tired or under the influence of drugs, alcohol or 
medication. A moment of inattention while operating power tools may result in serious 
personal injury. 

 

Use safety equipment. Always wear eye protection. Safety equipment such as dust mask, 
non-skid safety shoes, hard hat, or hearing protection used whenever conditions require 
will reduce personal injuries. 

 

Avoid accidental starting. Ensure the switch is in the off position before plugging in. 
Carrying power tools with your finger on the switch or plugging in power tools that have 
the switch on invites accidents. 

 

Remove any adjusting key or wrench before turning the power tool on. A wrench or a key 
left attached to a rotating part of the power tool may result in personal injury. 

 

Do not overreach. Keep proper footing and balance at all times. This enables better 
control of the power tool in unexpected situations. 

 

Dress properly. Do not wear loose clothing or jewellery. Keep your hair, clothing and 
gloves away from moving parts. Loose clothes, jewellery or long hair can be caught in 
moving parts. 

 

If devices are provided for the connection of dust extraction and collection facilities, ensure 
these are connected and properly used. Use of these devices can reduce dust related 
hazards.  

4.4 

Power tool use and care  

 

Do not force the power tool. Use the correct power tool for your application. The correct 
power tool will do the job better and safer at the rate for which it was designed. 

 

Do not use the power tool if the switch does not turn it on and off. Any power tool that 
cannot be controlled with the switch is dangerous and must be repaired. 

 

Disconnect the plug from the power source before making any adjustments, changing 
accessories, or storing power tools. Such preventive safety measures reduce the risk of 
starting the power tool accidentally. 

 

Store idle power tools out of the reach of children and do not allow persons unfamiliar with 
the power tool or these instructions to operate the power tool. Power tools are dangerous 
in the hands of untrained users. 

 

Maintain power tools. Check for misalignment or sticking of moving parts, breakage of 
parts and any other condition that may affect the power tool’s operation. If damaged, have 
the power tool repaired before use. Many accidents are caused by poorly maintained 
power tools. 

 

Keep cutting tools sharp and clean. Properly maintained cutting tools with sharp cutting 
edges are less likely to stick and are easier to control. 

 

Use the power tool, accessories and tool bits etc., in accordance with these instructions 
and in the manner intended for the particular type of power tool, taking into account the 
working conditions and the work to be performed. Use of the power tool for operations 
different from intended could lead to a hazardous situation. 

4.5 

Service 

 

Have your power tool serviced by a qualified repair person using only identical 
replacement parts. This will ensure that the safety of the power tool is maintained. 

 

 

Summary of Contents for POWX1706

Page 1: ... 5 2 Don ts 7 6 OPERATION 8 6 1 Switching on and off 8 6 1 1 Switching the appliance on 8 6 1 2 Switching the appliance off 8 6 2 Compressed air hose with quick coupler 5 8 6 2 1 Connecting 8 6 2 2 Cutting 8 6 3 Inflation 8 6 3 1 Using the adapter 8 6 3 2 Using the valve adapter 13 9 6 3 3 Using the ball needle 12 universal adapter 11 10 6 3 4 Using the adapter set 10 6 3 5 Using with the extensio...

Page 2: ...POWX1706 EN Copyright 2021 VARO P a g e 2 www varo com 12 DECLARATION OF CONFORMITY 12 ...

Page 3: ...ter for the nozzle set 19 Extension nozzle 20 Quick connector air outlet 2 PACKAGE CONTENT LIST Remove all packing materials Remove remaining packaging and transit supports if existing Check the completeness of the packing content Check the appliance the power cord the power plug and all accessories for transportation damages Keep the packaging materials as far as possible till the end of the warr...

Page 4: ...ids gases or dust Power tools create sparks which may ignite the dust or fumes Keep children and bystanders away while operating a power tool Distractions can cause you to lose control 4 2 Electrical safety Always check that the power supply corresponds to the voltage on the rating plate Power tool plugs must match the outlet Never modify the plug in any way Do not use any adapter plugs with earth...

Page 5: ... of these devices can reduce dust related hazards 4 4 Power tool use and care Do not force the power tool Use the correct power tool for your application The correct power tool will do the job better and safer at the rate for which it was designed Do not use the power tool if the switch does not turn it on and off Any power tool that cannot be controlled with the switch is dangerous and must be re...

Page 6: ...nd personal injury Protect the hoses against kinking constriction solvents and sharp edges Ensure that the hose clamps are always tight Loose or damaged hose clamps can allow air to escape in an uncontrolled manner Replace a damaged hose immediately A faulty supply line can cause a compressed air hose to thrash about and cause personal injury Do not breath in the exhaust air directly The hose must...

Page 7: ...xcess current take off The motor restarts automatically when normal temperature conditions are restored 5 2 Don ts Never direct the jet of air towards persons animals or your body Never let the compressor come into contact with water or other liquids and never direct the jet of liquids sprayed by tools connected to the compressor towards the compressor as the appliance is live this could cause ele...

Page 8: ...15 of the period in other words 1 5 minutes During the rest of the time period cooling phase 8 5 minutes the appliance cools down again 6 2 Compressed air hose with quick coupler 5 6 2 1 Connecting Push the compressed air connector 9 into the quick coupler of the compressed air hose 5 the sleeve automatically springs forwards 6 2 2 Cutting Pull back the sleeve on the quick coupler of the compresse...

Page 9: ... socket Switch the ON OFF switch 1 to I Read the air pressure from the manometer 6 Switch the ON OFF switchto 1 O as soon as the correct or permissible air pressure has been reached Press down the lever quick coupler 9 and pull it off the valve Remove the mains plug 4 from the mains power socket 6 3 2 Using the valve adapter 13 Sclaverand valve race valve Dunlop valve bicycle valve Area of use The...

Page 10: ... Use the deflating valve adapter 15 for this purpose The two tapered universal adapters 14 11 can also be used to inflate air mattresses 6 3 5 Using with the extension nozzle 19 The extension nozzle 19 is used for cleaning blowing out of concealed spaces or hard to reach areas as well as for the cleaning of contaminated equipment The infinitely variable trigger 10 allows an exact dosage of the com...

Page 11: ...rvice centre for Powerplus tools You can always obtain more information at the number 00 32 3 292 92 90 Any transportation costs shall always be borne by the customer unless agreed otherwise in writing At the same time no claim can be made on the warranty if the damage of the device is the result of negligent maintenance or overload Definitely excluded from the warranty is damage resulting from fl...

Page 12: ...rmity with the essential requirements and other relevant provisions of the applicable European Directives based on the application of European harmonized standards Any unauthorized modification of the apparatus voids this declaration European Directives including if applicable their amendments up to the date of signature 2011 65 EU 2006 42 EC 2014 30 EU 2000 14 EC Annex VI LwA Measured 96 dB A Gua...