background image

 

POWX1790 

EN

 

Copyright © 2017 VARO 

P a g e

 | 

5

 

www.varo.com 

 

Never use the appliance with bare feet or wet hands or feet. 

 

Never pull the power cable to disconnect the plug from the socket or to move the 
compressor. 

 

Never leave the appliance exposed to adverse weather conditions. 

 

Never transport the compressor with the receiver under pressure. 

 

Do not weld or machine the receiver. In the case of faults or rusting, replace the entire 
receiver. 

 

Never allow inexpert persons to use the compressor. Keep children and animals at a 
distance from the work area. 

 

Do not position flammable or nylon/fabric objects closed to and/or on the compressor. 

 

Never clean the compressor with flammable liquids or solvents. Check that you have 
unplugged the compressor and clean with a damp cloth only. 

 

The compressor must be used only for air compression. Do not use the compressor for 
any other type of gas. 

 

The compressed air produced by the compressor cannot not be used for pharmaceutical, 
food or medical purposes except after particular treatments and cannot be used to fill the 
air bottles of scuba divers. 

5.3 

Things you should know 

 

To avoid overheating of the electric motor, this compressor is designed for intermittent 
operation as indicated on the technical dataplate (for example, S3-25 means 2.5 minutes 
ON, 7.5 minutes OFF). In the case of overheating, the thermal cutout of the motor trips, 
automatically cutting off the power when the temperature is too high. The motor restarts 
automatically when normal temperature conditions are restored. 

 

To facilitate restart of the compressor, in addition to the operations indicated, it is 
important to return the button of the pressure switch to the OFF position and then to ON 
again (figures 2-3-4). 

 

On certain «V» type versions, the reset button on the terminal box of the motor must be 
pressed (fig. 5). 

 

On three-phase versions, simply return the button of the pressure switch to the ON 
position. (fig. 3). 

 

Single-phase versions are fitted with a pressure switch equipped with a delayed closing air 
discharge valve which facilitates start-up of the motor. Therefore venting of air from this 
valve for a few seconds with the receiver empty is normal. 

 

All the compressors are fitted with a safety valve that is tripped in the case of 
malfunctioning of the pressure switch in order to assure machine safety. 

 

When fitting a tool, the flow of air in output must be switched off. 

 

When using compressed air, you must know and comply with the safety precautions to be 
adopted for each type of application (inflation, pneumatic tools, painting, washing with 
water-based detergents only, etc.). 

6  START-UP AND USE 

 

Fit the wheels and foot (or the suckers according to model) following the instructions 
provided in the packaging. 

 

Check for correspondence between the compressor plate data with the actual 
specifications of the electrical system. A variation of ± 10% with respect of the rated value 
is allowed. 

 

Insert the plug of the power cable in a suitable socket (fig. 6) checking that the button of 
the pressure switch located on the compressor is in the OFF «O» position. 

 

For lubricated models, check the oil level using the rod included in the oil fuel plug (figures 
7a-7b-7c) or the sight glass (fig. 7d), and if necessary top up. 

 

At this point, the compressor is ready for use. 

 

Operating on the switch of the pressure switch (fig. 3), the compressor starts, pumping air 
into the receiver through the delivery pipe. 

Summary of Contents for POWX1790

Page 1: ...l safety 3 4 3 Personal safety 3 4 4 Power tool use and care 4 4 5 Service 4 5 PRECAUTIONS 4 5 1 Things to do 4 5 2 Things not to do 4 5 3 Things you should know 5 6 START UP AND USE 5 7 TECHNICAL DATA 6 8 SOUND EMISSION 6 9 MAINTENANCE 6 10 MAINTENANCE SCHEDULE 7 11 POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES 7 12 WARRANTY 8 13 ENVIRONMENT 8 14 DECLARATION OF CONFORMITY 9 ...

Page 2: ...ossible till the end of the warranty period Dispose it into your local waste disposal system afterwards WARNING Packaging materials are not toys Children must not play with plastic bags Danger of suffocation Compressor Manual If any parts are missing or damaged please contact your dealer 3 SYMBOLS In this manual and or on the machine the following symbols are used Before use read the handbook care...

Page 3: ...oor use reduces the risk of electric shock If operating a power tool in a damp location is unavoidable use a residual current device RCD protected supply Use of an RCD reduces the risk of electric shock 4 3 Personal safety Stay alert watch what you are doing and use common sense when operating a power tool Do not use a power tool while you are tired or under the influence of drugs alcohol or medic...

Page 4: ...ervice Have your power tool serviced by a qualified repair person using only identical replacement parts This will ensure that the safety of the power tool is maintained 5 PRECAUTIONS 5 1 Things to do The compressor must be used in a suitable environment well ventilated with an ambient temperature of between 5 C and 40 C and never in places affected by dust acids vapors explosive or flammable gase...

Page 5: ...indicated it is important to return the button of the pressure switch to the OFF position and then to ON again figures 2 3 4 On certain V type versions the reset button on the terminal box of the motor must be pressed fig 5 On three phase versions simply return the button of the pressure switch to the ON position fig 3 Single phase versions are fitted with a pressure switch equipped with a delayed...

Page 6: ...eumatic tools After setting the value required push the knob to fasten this fig 9b On some versions the ring nut underneath must be tightened to fasten the knob figures 9c 9d The value set can be checked on the gauge Please check that the air consumption and the maximum working pressure of the pneumatic tool to be used are compatible with the pressure set on the pressure regulator and with the amo...

Page 7: ...ting Draining tank condensate Periodically and at the end of work 11 POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES FAULT CAUSE REMEDY Leakage of air from the valve of the pressure switch with the compressor off Check valve that due to wear or dirt on the seal does not perform its function correctly Unscrew the hexagonal head of the check valve clean the valve seat and the special rubber disk repl...

Page 8: ...e dust penetration intentional damage on purpose or by gross carelessness inappropriate usage use for purposes for which the device is not suitable incompetent usage e g not following the instructions given in the manual inexpert assembly lightning strike erroneus net voltage This list is not exhaustive Acceptance of claims under warranty can never lead to the prolongation of the warranty period n...

Page 9: ...us voids this declaration European Directives including if applicable their amendments up to the date of signature 2011 65 EU 2014 30 EC 2006 42 EC 2000 14 EC Annex VI LwA 91dB A 94dB A Testing Authority Eurofins Modulo Uno Torino IT European harmonized standards including if applicable their amendments up to the date of signature EN1012 1 2010 EN60204 1 2006 EN55014 1 2006 EN55014 2 1997 EN61000 ...

Reviews: