After loosening any safety screws (fig. 12a), clean the intake filter according to the type of
working environment and at least every 100 hours (figures 12b-12c). If necessary, replace
the filter element (clogging of the filter reduces compressor performance and an inefficient
filter causes increased wear).
For lubricated models, replace the oil after the first 100 hours of operation and every 300
hours subsequently (figures 13a-13b-13c). Remember to check the oil level at regular
intervals. Use API CC/SC SAE 40. (For cold climates, API CC/SC SAE 20 is
recommended). Never mix different grade oils. If the oil changes color (whitish = presence
of water; dark = overheated), it is good practice to replace the oil immediately.
Periodically (or after working with the compressor for more than an hour), drain the
condensate that forms inside the receiver (fig. 11) due to the humidity in the air. This
protects the receiver from corrosion and does not restrict its capacity.
Spent oil (lubricated models) and condensate MUST BE DISPOSED OF in accordance
with environmental protection regulations and current legislation.
10 MAINTENANCE SCHEDULE
Cleaning of intake filter and/ or substitution of filtering element: every 100 hours
Change of oil: After the first 100 hours + every 300 hours
Tightening of head tension rods: The check must be carried out prior to the first
compressor starting
Draining tank condensate: Periodically and at the end of work
11 POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES
FAULT
CAUSE
REMEDY
Leakage of air from the
valve of the pressure
switch with the
compressor off.
Check valve that, due to wear
or dirt on the seal, does not
perform its function correctly.
Unscrew the hexagonal head of
the check valve, clean the valve
seat and the special rubber disk
(replace if worn). Reassemble
and tighten carefully (figures
14a-14b).
Reduction of
performance. Frequent
start-up. Low pressure
values.
Excessive performance
request, check for any leaks
from the couplings and/or
pipes. Intake filter may be
clogged.
Replace the seals of the fitting,
clean or replace the filter.
The compressor stops
and restarts
automatically after a few
minutes. In the V, 3 HP
versions, it is does not
start.
Tripping of the thermal cutout
due to overheating of the
motor.
Clean the air ducts in the
conveyor. Ventilate the work
area. Reset the thermal cutout.
On lubricated and V type
models, check oil level and
quality. On V models, have the
voltage checked.
After a few attempts to
restart, the compressor.
Tripping of the thermal cutout
due to overheating of the
motor (removal of the plug
with the compressor running,
low power voltage).
Activate the on/off switch.
Ventilate the work area. Wait a
few minutes. The compressor
will restart independently. On V,
3 HP models, reset the thermal
cutout. Remove any power
cable extensions
The compressor does
not stop and the safety
valve is tripped.
Irregular functioning of the
compressor or breakage of the
pressure switch.
Remove the plug and contact
the Service Center.