12 WARRANTY 

 

This product is warranted as provided by law for a 36-month period effective from the date 
of purchase by the first user. 

 

This warranty covers all material or production flaws excluding : batteries, chargers, 
defective parts subject to normal wear & tear such as bearings, brushes, cables, and 
plugs, or accessories such as drills, drill bits, saw blades, etc. ; damage or defects 
resulting from maltreatment, accidents or alterations; nor the cost of transportation. 

 

Damage and/or defects resulting from inappropriate use also do not fall under the 
warranty provisions. 

 

We also disclaim all liability for any bodily injury resulting from inappropriate use of the 
tool. 

 

Repairs may only be carried out by an authorised customer service centre for Powerplus 
tools. 

 

You can always obtain more information at the number 00 32 3 292 92 90. 

 

Any transportation costs shall always be borne by the customer, unless agreed otherwise 
in writing. 

 

At the same time, no claim can be made on the warranty if the damage of the device is the 
result of negligent maintenance or overload. 

 

Definitely excluded from the warranty is damage resulting from fluid permeation, excessive 
dust penetration, intentional damage (on purpose or by gross carelessness), inappropriate 
usage (use for purposes for which the device is not suitable), incompetent usage (e.g. not 
following the instructions given in the manual), inexpert assembly, lightning strike, 
erroneus net voltage. This list is not exhaustive. 

 

Acceptance of claims under warranty can never lead to the prolongation of the warranty 
period nor commencement of a new warranty period in case of a device replacement. 

 

Devices or parts which are replaced under the warranty  therefore remain the property of 
Varo NV. 

 

 We reserve the right to reject a claim whenever the purchase cannot be verified or when it 
is clear that the product has not been properly maintained. (Clean ventilation slots, carbon 
brushes serviced regularly, etc.). 

 

Your purchase receipt must be kept as proof of date of purchase. 

 

Your appliance must be returned undismantled to your dealer in an acceptably clean state, 
(in its original blow-moulded case if applicable to the unit), accompanied by proof of 
purchase. 

13 ENVIRONMENT 

Should  your  appliance  need  replacement  after  extended  use,  do  not  discard  it 
with the household rubbish but dispose of it in an environmentally safe way. 
Waste  produced  by  electrical  machine  items  should  not  be  handled  like  normal 
household rubbish. Please recycle where recycle facilities exist. Check with your 
Local Authority or retailer for recycling advice. 

 

 

Summary of Contents for POWX1790

Page 1: ...l safety 3 4 3 Personal safety 3 4 4 Power tool use and care 4 4 5 Service 4 5 PRECAUTIONS 4 5 1 Things to do 4 5 2 Things not to do 4 5 3 Things you should know 5 6 START UP AND USE 5 7 TECHNICAL DATA 6 8 SOUND EMISSION 6 9 MAINTENANCE 6 10 MAINTENANCE SCHEDULE 7 11 POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES 7 12 WARRANTY 8 13 ENVIRONMENT 8 14 DECLARATION OF CONFORMITY 9 ...

Page 2: ...ossible till the end of the warranty period Dispose it into your local waste disposal system afterwards WARNING Packaging materials are not toys Children must not play with plastic bags Danger of suffocation Compressor Manual If any parts are missing or damaged please contact your dealer 3 SYMBOLS In this manual and or on the machine the following symbols are used Before use read the handbook care...

Page 3: ...oor use reduces the risk of electric shock If operating a power tool in a damp location is unavoidable use a residual current device RCD protected supply Use of an RCD reduces the risk of electric shock 4 3 Personal safety Stay alert watch what you are doing and use common sense when operating a power tool Do not use a power tool while you are tired or under the influence of drugs alcohol or medic...

Page 4: ...ervice Have your power tool serviced by a qualified repair person using only identical replacement parts This will ensure that the safety of the power tool is maintained 5 PRECAUTIONS 5 1 Things to do The compressor must be used in a suitable environment well ventilated with an ambient temperature of between 5 C and 40 C and never in places affected by dust acids vapors explosive or flammable gase...

Page 5: ...indicated it is important to return the button of the pressure switch to the OFF position and then to ON again figures 2 3 4 On certain V type versions the reset button on the terminal box of the motor must be pressed fig 5 On three phase versions simply return the button of the pressure switch to the ON position fig 3 Single phase versions are fitted with a pressure switch equipped with a delayed...

Page 6: ...eumatic tools After setting the value required push the knob to fasten this fig 9b On some versions the ring nut underneath must be tightened to fasten the knob figures 9c 9d The value set can be checked on the gauge Please check that the air consumption and the maximum working pressure of the pneumatic tool to be used are compatible with the pressure set on the pressure regulator and with the amo...

Page 7: ...ting Draining tank condensate Periodically and at the end of work 11 POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES FAULT CAUSE REMEDY Leakage of air from the valve of the pressure switch with the compressor off Check valve that due to wear or dirt on the seal does not perform its function correctly Unscrew the hexagonal head of the check valve clean the valve seat and the special rubber disk repl...

Page 8: ...e dust penetration intentional damage on purpose or by gross carelessness inappropriate usage use for purposes for which the device is not suitable incompetent usage e g not following the instructions given in the manual inexpert assembly lightning strike erroneus net voltage This list is not exhaustive Acceptance of claims under warranty can never lead to the prolongation of the warranty period n...

Page 9: ...us voids this declaration European Directives including if applicable their amendments up to the date of signature 2011 65 EU 2014 30 EC 2006 42 EC 2000 14 EC Annex VI LwA 91dB A 94dB A Testing Authority Eurofins Modulo Uno Torino IT European harmonized standards including if applicable their amendments up to the date of signature EN1012 1 2010 EN60204 1 2006 EN55014 1 2006 EN55014 2 1997 EN61000 ...

Reviews: