background image

 

POWX1790 

EN

 

Copyright © 2017 VARO 

P a g e

 | 

4

 

www.varo.com 

4.4 

Power tool use and care  

 

Do not force the power tool. Use the correct power tool for your application. The correct 
power tool will do the job better and safer at the rate for which it was designed. 

 

Do not use the power tool if the switch does not turn it on and off. Any power tool that 
cannot be controlled with the switch is dangerous and must be repaired. 

 

Disconnect the plug from the power source before making any adjustments, changing 
accessories, or storing power tools. Such preventive safety measures reduce the risk of 
starting the power tool accidentally. 

 

Store idle power tools out of the reach of children and do not allow persons unfamiliar with 
the power tool or these instructions to operate the power tool. Power tools are dangerous 
in the hands of untrained users. 

 

Maintain power tools. Check for misalignment or sticking of moving parts, breakage of 
parts and any other 

condition that may affect the power tool’s operation. If damaged, have 

the power tool repaired before use. Many accidents are caused by poorly maintained 
power tools. 

 

Keep cutting tools sharp and clean. Properly maintained cutting tools with sharp cutting 
edges are less likely to stick and are easier to control. 

 

Use the power tool, accessories and tool bits etc., in accordance with these instructions 
and in the manner intended for the particular type of power tool, taking into account the 
working conditions and the work to be performed. Use of the power tool for operations 
different from intended could lead to a hazardous situation. 

4.5 

Service 

 

Have your power tool serviced by a qualified repair person using only identical 
replacement parts. This will ensure that the safety of the power tool is maintained. 

5  PRECAUTIONS 

5.1 

Things to do 

 

The compressor must be used in a suitable environment (well ventilated with an ambient 
temperature of b5°C and +40°C) and never in places affected by dust, acids, 
vapors, explosive or flammable gases. 

 

Always maintain a safety distance of at least 4 meters between the compressor and the 
work area. 

 

Any coloring of the belt guards of the compressor during painting operations indicates that 
the distance is too short. 

 

Insert the plug of the electric cable in a socket of suitable shape, voltage and frequency 
complying with current regulations. 

 

For three-phase versions have the plug fitted by a qualified electrician according to local 
regulations. The first time you start the compressor, check that the direction of rotation is 
correct and matches that indicated by the arrow on the conveyor (Fig. 1, the air must be 
conveyed towards the head of the compressor). 

 

Use extension cables with a maximum length of 5 meters and of suitable cross-section. 

 

The use of extension cables of different length and also of adapters and multiple sockets 
should be avoided. 

 

Always use the switch of the pressure switch to switch off the compressor 

 

Always use the handle to move the compressor. 

 

When operating, the compressor must be placed on a stable, horizontal surface to 
guarantee correct lubrication. 

5.2 

Things not to do 

 

Never direct the jet of air towards persons, animals or your body. (Always wear safety 
goggles to protect your eyes against flying objects that may be lifted by the jet of air). 

 

Never direct the jet of liquids sprayed by tools connected to the compressor towards the 
compressor. 

Summary of Contents for POWX1790

Page 1: ...l safety 3 4 3 Personal safety 3 4 4 Power tool use and care 4 4 5 Service 4 5 PRECAUTIONS 4 5 1 Things to do 4 5 2 Things not to do 4 5 3 Things you should know 5 6 START UP AND USE 5 7 TECHNICAL DATA 6 8 SOUND EMISSION 6 9 MAINTENANCE 6 10 MAINTENANCE SCHEDULE 7 11 POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES 7 12 WARRANTY 8 13 ENVIRONMENT 8 14 DECLARATION OF CONFORMITY 9 ...

Page 2: ...ossible till the end of the warranty period Dispose it into your local waste disposal system afterwards WARNING Packaging materials are not toys Children must not play with plastic bags Danger of suffocation Compressor Manual If any parts are missing or damaged please contact your dealer 3 SYMBOLS In this manual and or on the machine the following symbols are used Before use read the handbook care...

Page 3: ...oor use reduces the risk of electric shock If operating a power tool in a damp location is unavoidable use a residual current device RCD protected supply Use of an RCD reduces the risk of electric shock 4 3 Personal safety Stay alert watch what you are doing and use common sense when operating a power tool Do not use a power tool while you are tired or under the influence of drugs alcohol or medic...

Page 4: ...ervice Have your power tool serviced by a qualified repair person using only identical replacement parts This will ensure that the safety of the power tool is maintained 5 PRECAUTIONS 5 1 Things to do The compressor must be used in a suitable environment well ventilated with an ambient temperature of between 5 C and 40 C and never in places affected by dust acids vapors explosive or flammable gase...

Page 5: ...indicated it is important to return the button of the pressure switch to the OFF position and then to ON again figures 2 3 4 On certain V type versions the reset button on the terminal box of the motor must be pressed fig 5 On three phase versions simply return the button of the pressure switch to the ON position fig 3 Single phase versions are fitted with a pressure switch equipped with a delayed...

Page 6: ...eumatic tools After setting the value required push the knob to fasten this fig 9b On some versions the ring nut underneath must be tightened to fasten the knob figures 9c 9d The value set can be checked on the gauge Please check that the air consumption and the maximum working pressure of the pneumatic tool to be used are compatible with the pressure set on the pressure regulator and with the amo...

Page 7: ...ting Draining tank condensate Periodically and at the end of work 11 POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES FAULT CAUSE REMEDY Leakage of air from the valve of the pressure switch with the compressor off Check valve that due to wear or dirt on the seal does not perform its function correctly Unscrew the hexagonal head of the check valve clean the valve seat and the special rubber disk repl...

Page 8: ...e dust penetration intentional damage on purpose or by gross carelessness inappropriate usage use for purposes for which the device is not suitable incompetent usage e g not following the instructions given in the manual inexpert assembly lightning strike erroneus net voltage This list is not exhaustive Acceptance of claims under warranty can never lead to the prolongation of the warranty period n...

Page 9: ...us voids this declaration European Directives including if applicable their amendments up to the date of signature 2011 65 EU 2014 30 EC 2006 42 EC 2000 14 EC Annex VI LwA 91dB A 94dB A Testing Authority Eurofins Modulo Uno Torino IT European harmonized standards including if applicable their amendments up to the date of signature EN1012 1 2010 EN60204 1 2006 EN55014 1 2006 EN55014 2 1997 EN61000 ...