After loosening any safety screws (fig. 12a), clean the intake filter according to the type of 
working environment and at least every 100 hours (figures 12b-12c). If necessary, replace 
the filter element (clogging of the filter reduces compressor performance and an inefficient 
filter causes increased wear). 

 

For lubricated models, replace the oil after the first 100 hours of operation and every 300 
hours subsequently (figures 13a-13b-13c). Remember to check the oil level at regular 
intervals. Use API CC/SC SAE 40. (For cold climates, API CC/SC SAE 20 is 
recommended). Never mix different grade oils. If the oil changes color (whitish = presence 
of water; dark = overheated), it is good practice to replace the oil immediately. 

 

Periodically (or after working with the compressor for more than an hour), drain the 
condensate that forms inside the receiver (fig. 11) due to the humidity in the air. This 
protects the receiver from corrosion and does not restrict its capacity. 

 

Spent oil (lubricated models) and condensate MUST BE DISPOSED OF in accordance 
with environmental protection regulations and current legislation. 

10 MAINTENANCE SCHEDULE 

 

Cleaning of intake filter and/ or substitution of filtering element: every 100 hours 

 

Change of oil: After the first 100 hours + every 300 hours 

 

Tightening of head tension rods: The check must be carried out prior to the first 
compressor starting 

 

Draining tank condensate: Periodically and at the end of work 

11 POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES 

FAULT 

CAUSE 

REMEDY 

Leakage of air from the 
valve of the pressure 
switch with the 
compressor off. 

Check valve that, due to wear 
or dirt on the seal, does not 
perform its function correctly. 

Unscrew the hexagonal head of 
the check valve, clean the valve 
seat and the special rubber disk 
(replace if worn). Reassemble 
and tighten carefully (figures 
14a-14b). 

Reduction of 
performance. Frequent 
start-up. Low pressure 
values. 

Excessive performance 
request, check for any leaks 
from the couplings and/or 
pipes. Intake filter may be 
clogged. 

Replace the seals of the fitting, 
clean or replace the filter. 

The compressor stops 
and restarts 
automatically after a few 
minutes. In the V, 3 HP 
versions, it is does not 
start. 

Tripping of the thermal cutout 
due to overheating of the 
motor. 

Clean the air ducts in the 
conveyor. Ventilate the work 
area. Reset the thermal cutout. 
On lubricated and V type 
models, check oil level and 
quality. On V models, have the 
voltage checked. 

After a few attempts to 
restart, the compressor. 

Tripping of the thermal cutout 
due to overheating of the 
motor (removal of the plug 
with the compressor running, 
low power voltage). 

Activate the on/off switch. 
Ventilate the work area. Wait a 
few minutes. The compressor 
will restart independently. On V, 
3 HP models, reset the thermal 
cutout. Remove any power 
cable extensions 

The compressor does 
not stop and the safety 
valve is tripped. 

Irregular functioning of the 
compressor or breakage of the 
pressure switch. 

Remove the plug and contact 
the Service Center. 

Summary of Contents for POWX1790

Page 1: ...l safety 3 4 3 Personal safety 3 4 4 Power tool use and care 4 4 5 Service 4 5 PRECAUTIONS 4 5 1 Things to do 4 5 2 Things not to do 4 5 3 Things you should know 5 6 START UP AND USE 5 7 TECHNICAL DATA 6 8 SOUND EMISSION 6 9 MAINTENANCE 6 10 MAINTENANCE SCHEDULE 7 11 POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES 7 12 WARRANTY 8 13 ENVIRONMENT 8 14 DECLARATION OF CONFORMITY 9 ...

Page 2: ...ossible till the end of the warranty period Dispose it into your local waste disposal system afterwards WARNING Packaging materials are not toys Children must not play with plastic bags Danger of suffocation Compressor Manual If any parts are missing or damaged please contact your dealer 3 SYMBOLS In this manual and or on the machine the following symbols are used Before use read the handbook care...

Page 3: ...oor use reduces the risk of electric shock If operating a power tool in a damp location is unavoidable use a residual current device RCD protected supply Use of an RCD reduces the risk of electric shock 4 3 Personal safety Stay alert watch what you are doing and use common sense when operating a power tool Do not use a power tool while you are tired or under the influence of drugs alcohol or medic...

Page 4: ...ervice Have your power tool serviced by a qualified repair person using only identical replacement parts This will ensure that the safety of the power tool is maintained 5 PRECAUTIONS 5 1 Things to do The compressor must be used in a suitable environment well ventilated with an ambient temperature of between 5 C and 40 C and never in places affected by dust acids vapors explosive or flammable gase...

Page 5: ...indicated it is important to return the button of the pressure switch to the OFF position and then to ON again figures 2 3 4 On certain V type versions the reset button on the terminal box of the motor must be pressed fig 5 On three phase versions simply return the button of the pressure switch to the ON position fig 3 Single phase versions are fitted with a pressure switch equipped with a delayed...

Page 6: ...eumatic tools After setting the value required push the knob to fasten this fig 9b On some versions the ring nut underneath must be tightened to fasten the knob figures 9c 9d The value set can be checked on the gauge Please check that the air consumption and the maximum working pressure of the pneumatic tool to be used are compatible with the pressure set on the pressure regulator and with the amo...

Page 7: ...ting Draining tank condensate Periodically and at the end of work 11 POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES FAULT CAUSE REMEDY Leakage of air from the valve of the pressure switch with the compressor off Check valve that due to wear or dirt on the seal does not perform its function correctly Unscrew the hexagonal head of the check valve clean the valve seat and the special rubber disk repl...

Page 8: ...e dust penetration intentional damage on purpose or by gross carelessness inappropriate usage use for purposes for which the device is not suitable incompetent usage e g not following the instructions given in the manual inexpert assembly lightning strike erroneus net voltage This list is not exhaustive Acceptance of claims under warranty can never lead to the prolongation of the warranty period n...

Page 9: ...us voids this declaration European Directives including if applicable their amendments up to the date of signature 2011 65 EU 2014 30 EC 2006 42 EC 2000 14 EC Annex VI LwA 91dB A 94dB A Testing Authority Eurofins Modulo Uno Torino IT European harmonized standards including if applicable their amendments up to the date of signature EN1012 1 2010 EN60204 1 2006 EN55014 1 2006 EN55014 2 1997 EN61000 ...

Reviews: