background image

Attribute

Symbol

Value

Units

Model 

I

dentification

Annual Energy Consumption

AEC

Hood

kWh

Time Increase factor

f

FDE

Hood

EEI

Hood

Measured Airflow at Best

Q

BEP

m

3

/h

Measured Pressure at Best 

P

BEP

Pa

Maximum Airflow

Q

MAX

m

3

/h

Measured Electric Power at Best

W

BEP

W

Nominal  Lighting Power

WL

W

Average I llumination of the

lighting system on the cooking 

surface

E

Middle

Lux

Measured Power Consumption

in standby

P

S

W

Measured Power Consumption

P

O

W

Noise level

L

WA

dBA

GFE

Hood

%

LE

Hood

P21561XBSS

%

12

PowerPoint

15.1

1.7

8.7

52.8

  

181.9

39

285.1

22.6

1.5

74

--

0.0

52

57.8 (E)

49 (A)

Summary of Contents for P21561XBSS

Page 1: ...Cod 0103087104 00 03 P21561XBSS Extractors Installation use and maintenance ...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ... circulated air requires the use of charcoal filters to remove odours To ensure the best performance from your cooker hood the charcoal filter should be replaced every 3 6 months dependent on use Check with your local retailer or dealer for information on how to obtain replacement charcoal filters Note This charcoal filter is non washable and must be replaced as required To install a new charcoal ...

Page 6: ...1X1 5W LED MAX P21561XBSS 6 ...

Page 7: ...FUSE 3A PROTECTION LINE 3A Fuse is installed inside the plug to protection line 26 5W 230 240V ac 50Hz 7 ...

Page 8: ...8 ...

Page 9: ...A B C D E F P21561XBSS 9 60 5 120 5 175 75 80 Height dependent ...

Page 10: ...E DAMAGE TO THE INTERNAL WIRING WHICH WILL NOT BE COVERED BY THE WARRANTY 10mm Fig 5 Fig 6 Fig 7 Fig 8 Fig 9 Fig 10 Tools required Mark wall as required see Fig 3 Drill 4 holes for mounting the body Fit wall fixings and top screws Ensure that any fixings you use are appropriate for the wall type 8 Mount chimney brackets INSTALLATION 10 ...

Page 11: ... storage This should be removed during installation by using a non abrasive stainless steel cleaner Always follow the instructions given with the cleaner being used Fig 13 Fig 14 Adjust and secure the chimney Adjust and secure the chimney 11 Fig 12 Fig 11 Fix ducting seal joint Mount the chimney t an t an ...

Page 12: ... Best PBEP Pa Maximum Airflow QMAX m3 h Measured Electric Power at Best WBEP W Nominal Lighting Power WL W Average Illumination of the lighting system on the cooking surface EMiddle Lux Measured Power Consumption in standby PS W Measured Power Consumption PO W Noise level LWA dBA GFEHood LEHood P21561XBSS 12 PowerPoint 15 1 1 7 8 7 52 8 181 9 39 285 1 22 6 1 5 74 0 0 52 57 8 E 49 A ...

Page 13: ...12 ...

Reviews: