background image

air gun temperature up button

preheating station temperature up button

Figure3

air gun temperature up button

preheating station temperature up button

WARNING

In view of could cause serious injuries of fire accidents,please strictly observe the following
1.Must be confirmed well-connected handle and the machine, after that open the power supply
switch, all the parts removal or installed, must be turn off the power supply switch, then operate it
(High-Pressure is dangerous!)
2.When the power supply is turned, the air gun or soldering iron outlet temperature higher than 100
to 480 degrees Celsius (212-896 degrees Fahrenheit),the preheat plate surface  temperature  of
50-400 degrees Celsius(122-752 degrees Fahrenheit):DO NOT touch the air gun or soldering iron
metal part and preheat plate near the chassis,aluminum mesh,to replace nozzles or the tips and the
tips and other parts,should turn off the power supply and cooling to room temperature,then operate
it(Hihg-temperaturn is risk!)
3.DO NOT use the machine near flammable things(Fire hazard is dangerous!)

Terms

 

of

 

Use

1.Please ensure the Hot’s outlet is clear,  must free from any blockages or obstructions.
2.After the work  is  completed ,  the air gun handle pot   the frame or turn off air  gun  switch,  the
machine automatically cooled to display“---”stop the air,then turn off the whole device power switch
in the back of the chassis.
3.When using the machine standard three nozzles:big,middle,small nozzles other than the smaller
nozzle,must separate air volume was djusted to the maximum use of a lower temperature and in a
short use.Avoid prolonged use of the damage to the air gun.
4.In regards to the usage requirements,choose the appropriate Hot air flow,different Hot air flow will
cause the temperature to be slightly different,and please maintain the distance between the oulet
and the object must be at least 2 mm.
5.When the iron is used for the first time,please pay attention to check the iron tip warming condition,
when the tip can melt the tin wire,please plate some tini on tip,then adjust to the desired temperature.
6.The tip temperature should not be too high,too high temperature would weaken the tip function.
when interval using ,can lowering the temperature.
7.Should be regularly use clean sponge to clear  soldering tip,   after finish use ,should wipe clean
soldering iron tip,plate new tin to prevent soldering iron tip oxide.
8.Preheat plate non-turn on the water structure,  therefore, do not install the storage  and  use  of  
contact with oil,water,and plastic pellets to prevent leakage and other security risks.
9.The preheat plate should avoid being forced to tap or hard objects collided causing tiles fracture,
alloy resistance wire exposed affect the operating life.
10.The preheat plate DO NOT for prolonged use,and prevent chassis overheating.

Special Instructions:

Dear User! Our air gun and soldering iron handle adopt high strength stainless steel tube, the 
machine  must  be  inspected  or  calibrated  four  times  in  normal  working condition during the 
production process,the copper tube could be slight yellowing due to high temperature!When use
the new machine first time,  it is normal that the steel tube at tube at a slight yellowing, please be
assured!

Preheating station

Temperature Range

Temperature Stability

Display Type

Area

Hot Air Reworks

Airflow type

Air Flow

Temperature Range

Temperature Stability

Display Type

Handle cable length

Soldering Iron

Temperature Range

Temperature Stability

Tip of ground voltage

Tip ground impedance

Display Type

Handle cable length

Performance comparison table

Model

Function

Functional components Preheating station

Preheating station
+Hot air reworks

Preheating station

+Hot air

Soldering station

Display type                        LED                             LED                                      LED

Fahrenheit/Celsius

     Conversion                        NO                             YES                                      YES

NO                             YES                                      YES

Temperature correction                       

YES                            YES                                      YES

High temperature protection

Gun Type                               ---                       Brushless fan                    Brushless fan

Control Temperature way           Digital PID                    Digital PID                          Digital  PID                      

Operationg

1.Preheating station part

A.853A

1).Preheating station laid out      plugged

2).Move bracket card board will need to preheat the element is placed above the plate        move tighten the four screws  on  the

   bracket,tiexed need tto preheat components 

Summary of Contents for 853 Serises

Page 1: ...53serise Preheating station Hot air reworks soldering staiong combinationg 1 Cover 5 Preheating place 3 Preheating place bracket 4 Fasten 2 Screws Figure6 Preheat plate disassembly diagram Figure5 Soldering iron disassembly diagram Figure4 Hot air gun disassembly diagram ...

Page 2: ...ion Measurement Weight Working environment Storage environment The do s and don t s 1 DO NOT install De install Nozzles with excessive force DO NOT use pliers to pull the nozzle edge out DO NOT tight the nozzle s bolt exessively 2 Only install nozzles when the unit is cool room temperature 3 DO NOT use unit near flammable gas or liquid or any combustible material WHATSOEVER especially when using t...

Page 3: ... tin wire please plate some tini on tip then adjust to the desired temperature 6 The tip temperature should not be too high too high temperature would weaken the tip function when interval using can lowering the temperature 7 Should be regularly use clean sponge to clear soldering tip after finish use should wipe clean soldering iron tip plate new tin to prevent soldering iron tip oxide 8 Preheat ...

Page 4: ... processs with solder paste manufacturer specifications given parameters as possible and using a combination of the top and bottom of heating Bottom heating to complement the board due to pass of heat while elevated board temperature the top heating is used heating components in addition the use of coders bottom heater can be eliminated due to local over heating the circuit board caused by distort...

Reviews: