Step 7: Turn on the UPS 

Press the ON/Mute button on the front panel for two seconds to power on the UPS. 

Note: 

The battery charges fully during the first five hours of normal operation. Do not 

expect full battery run capability during this initial charge period. 

Step 8: Install software 

Install NetGuard UPS monitoring software to fully configure UPS shutdown. Please follow steps 
below to download and install monitoring software:

 

1. Go to the website 

http://www.powershield.com.au/downloads

2. Click NetGuard software icon and then choose your required OS to download the software.
3. Follow the on-screen instructions to install the software.
4. When your computer restarts, the monitoring software will appear as an orange plug icon
located in the system tray, near the clock. 

Summary of Contents for 1100 VA

Page 1: ...terruptible Power Supply System www powershield com au Commander RT 1100 2000 3000 VA Line Interactive Sinewave UPS IMPORTANT Download latest software www powershield com au downloads NetGuard User Ma...

Page 2: ...ags power surges under voltage over voltage line noise frequency variation switching transients and harmonic distortions The Commander RTs will continuously protect your equipment by internally isolat...

Page 3: ...nd the associated warning should be observed CAUTION REFER TO OPERATOR S MANUAL Refer to your operator s manual for additional information such as important operating and maintenance SAFETY EARTHING T...

Page 4: ...he UPS 7 2 3 Setup the UPS 7 3 Operations 10 3 1 Button Operation 10 3 2 LCD Panel 10 3 3 Audible Alarm 11 3 4 LCD Display Wordings Index 12 3 5 UPS Setting 12 3 6 Operating Mode Description 15 3 7 Fa...

Page 5: ...the UPS system near water or in moist environments Do not install the UPS system where it would be exposed to direct sunlight or near heater Do not block ventilation holes in the UPS housing 1 3 Inst...

Page 6: ...nect the batteries and verify that no current is present and no hazardous voltage exists in the terminals of high capability capacitor such as BUS capacitors Only persons are adequately familiar with...

Page 7: ...r Panel View PSCRT1100 PSCRT2000 PSCRT3000 1 Programmable outlets connect to non critical loads 2 Output receptacles connect to mission critical loads 3 AC input 4 Input circuit breaker 5 Emergency po...

Page 8: ...S input connection Plug the UPS into a two pole three wire grounded receptacle only Avoid using extension cords Step 2 UPS output connection There two kinds of outputs programmable outlets white colou...

Page 9: ...UPS it will provide advanced communication and monitoring options NOTE USB port and RS 232 port cannot work at the same time Step 5 EPO Emergency Power OFF function Keep the pin 1 and pin 2 closed fo...

Page 10: ...all software Install NetGuard UPS monitoring software to fully configure UPS shutdown Please follow steps below to download and install monitoring software 1 Go to the website http www powershield com...

Page 11: ...d hold this button at least 2 seconds to turn off the UPS Confirm selection key Press this button to confirm selection in UPS setting mode SELECT Button Switch LCD message Press this button to change...

Page 12: ...ion Indicates the load level by 0 25 26 50 51 75 and 76 100 Indicates overload Indicates the load or the UPS output is short circuited UPS status Indicates that programmable management outlets are wor...

Page 13: ...or program alternatives There are 4 programs to set up output voltage setting programmable outlets enable disable programmable outlets setting LCD display direction and exit 01 Output voltage setting...

Page 14: ...time limits in minutes from 0 999 for programmable outlets which connect to non critical devices on battery mode 04 LCD display direction setting Interface Setting RAC the LCD display is horizontal TO...

Page 15: ...ss and hold the Selection button for 5 seconds to enter Setting mode Step 3 Press the Up button ON MUTE to switch to 02 of program list Then press Enter button to enter value setting of parameter 2 Pr...

Page 16: ...s fully charged the fan will stop working for energy saving Buck mode when AC is normal When the input voltage is higher than the voltage regulation range but lower than high loss point the buck AVR w...

Page 17: ...x Inverter voltage high 12 x Over load 43 Inverter voltage Low 13 x 3 8 Warning Indicator Warning Icon flashing Alarm Low Battery Rapid one beep every second Overload 2 short beeps every 2 seconds Ba...

Page 18: ...ing 2 short beeps every 2 seconds The external or internal battery is incorrectly connected Check if all batteries are connected well Fault code is shown as 27 and the icon is lighting on LCD display...

Page 19: ...uipped with internal batteries and user can replace the batteries without shutting down the UPS or connected loads hot swappable battery design Replacement battery pack is a safe procedure and isolate...

Page 20: ...rst before installing it inside of UPS Please select correct battery kit procedure below to assemble it Battery kit for PSCRT1100 Step 1 Remove adhesive tapes Step 2 Connect all battery terminals by f...

Page 21: ...shells Step 4 Cover the other side of plastic shell as below chart Then battery kit is assembly well Battery kit for PSCRT3000 PSRTBB12 Step 1 Remove adhesive tapes Step 2 Connect all battery terminal...

Page 22: ...l to eliminate common problems 2 Verify that no input output circuit breaker are tripped A tripped circuit breaker is the most common problem 3 If the problem still persists please call 1300 305 393 f...

Page 23: ...ring charge the UPS 5 hours Store the UPS covered and upright in a cool dry location During storage recharge the battery in accordance with the following table Storage Temperature Recharge Frequency C...

Page 24: ...tems Linux Unix and Mac AC Mode Batt Mode Load Level Input Voltage Output Voltage Overload Fault Low Batt ProTeCTIon Full Protection Overload discharge thermal short circuit and overcharge protection...

Reviews: