14
06: Input Waveform Sensitivity
Interface
Setting
St1: Input voltage waveform detection is highly sensitive.
St2: Input voltage waveform detection is middle
sensitive. (Default)
St3: Input voltage waveform detection is low sensitive.
00: Exit setting
Steps for setting programmable outlet ( White Coloured Outlets )
Step 1:
Before entering setting mode, the UPS should be in Stand-by
mode (off-charging) and make sure the battery is connected.
The LCD display is shown as right.
Step 2:
Press and hold the
“
Selection
”
button for 5 seconds to enter
Setting mode.
Step 3:
Press the
“
Up
“
button (ON/MUTE) to switch to "02" of program
list. Then press
“E
nter
“ button
to enter value setting of
parameter 2. Press
the “Up” button
to change the value to
“
ENA
”
to enable the programmable outlet function. Then press
“
Enter
”
button again to confirm the setting.
Step 4:
Press the
“
Up
“
button (ON/MUTE) again to switch to "03" of
program list. Then press
“E
nter
“ button
for setting programmable
outlet time. P
ush “Up” button
to change the value of backup time
according your demand. Then press
“Enter”
to confirm the
setting.
Step 5:
Press
“
Up
“
button (ON/MUTE) to switch to "00" of program list. Then press
“
Enter
”
button
to exit setting menu.