Model #

PSD650

PSD1200

PSD1600

Capacity

650VA/390W

1200VA/720W

1600VA/960W

INPUT
Voltage (Nominal)

240Vac

Voltage Range

177-290Vac

Frequency Range

50/60Hz ± 5Hz

OUTPUT
Output Voltage

240 Vac

Output Voltage Regulation

240Vac ± 10%

Frequency

AC mode tracks utility

Frequency Range (Batt. Mode)

50Hz or 60Hz ± 1Hz

Transfer Time

Typical 2-6ms, 10ms max

Waveform (Batt. Mode)

Simulated Sine Wave

UPS & Surge Protection

2

3

Surge Protection

0

3

BATTERY
Battery Type & Number

12V 9AH (x1)

12V 7AH (x2)

12V 9AH (x2)

Backup Time (One PC Load @ 120W)

25min

40min

45min

Typical Recharge Time

4-6 Hours recover to 90% capacity

PROTECTION
Full Protection

Overload, discharge and overcharge protection

Surge Protection

312Joules/6500Amps

936Joules/19500Amps

Safety 

A-tick, EN62040-1-1 2003, IEC60950-1:2001

EMC

EN62040-2 2006

OPERATING ENVIRONMENT
Humidity

0-90% RH @ 0-40°C (non-condensing)

Noise Level

<5dB (no fan)

PHYSICAL
Dimensions (D x W x H)

(328 x 100 x 145)mm

(397 x 146 x 205)mm

Net Weight

5.2kg

11.1kg

11.5kg

Summary of Contents for defender PSD 650

Page 1: ...lated equipment such as medical equipment life support system microwave oven and vaccum cleaners Also since this unit output is not sinusoidal please do not connect AC line filters motors and other in...

Page 2: ...tteries 1 Remove watches rings and other metal objects 2 Use proper tools with insulated handles 3 Do not lay tools or metal parts on the top of batteries 4 Disconnect charging source prior to connect...

Page 3: ...Connect peripherals that do NOT need battery backup Connect USB cable and computer Install NetGuard UPS monitoring software for advanced power monitoring Breaker will trip when there is overload short...

Page 4: ...oring software from www powershield com au index php downloads 2 When the installation is completed NetGuard agent icon will appear on the Task bar 3 Once installation is completed click the plug icon...

Page 5: ...pull forward Please be careful not to apply excess force to the panel as it may cause damage to the LCD cable attached to it 5 Remove the metal plate holding the battery pack in the enclosure by slidi...

Page 6: ...rtation costs to ship the replacement to the customer within Australian capital cities metro areas only 1 Review the problems discussed in the troubleshoot section of this manual to eliminate common p...

Page 7: ...rge Protection 2 3 Surge Protection 0 3 BATTERY Battery Type Number 12V 9AH x1 12V 7AH x2 12V 9AH x2 Backup Time One PC Load 120W 25min 40min 45min Typical Recharge Time 4 6 Hours recover to 90 capaci...

Reviews: