Troubleshooting
Use the table below to solve mino UPS installation or operation problems. Consult Online Technical Support or call
Technical Support for assistance with problems that cannot be resolved using the table below:
-UPS will not turn on.after turning masster breaker
No power available at the Surge Protection
outlets.
Connected equipment loses power.
The Power On indicator is lit and the -
UPS is beeping four times every 30
seconds.
The Power On indicator flashes once per
second and the -UPS beeps once
per second at the same time.
Building Wiring Fault indicator is lit.
Inadequate runtime.
Battery is disconnected and utility power is not available at
the wall outlet.
Surge Protection outlets have been overloaded.
Utility power not available at the wall outlet.
Equipment is connected to the “Surge Protection” outlets.
The UPS is overloaded.
PowerChute Personal Edition software has performed a
shutdown due to a power failure.
The UPS has exhausted its available battery
power.
Connected equipment does not accept the step-
approximated sine waveform the UPS .
The -UPS may require service.
The UPS is using battery.
Battery capacity is low (about 2 minutes of use remaining).
Your building wiring presents a shock hazard. Using the
-UPS with this condition will void the warranty.
The battery is not fully charged.
Battery is near the end of useful life.
Connect the battery (see
Connect Battery
) and ensure power is available at the wall
outlet.
Reduce the amount of equipment plugged into Surge Protection outlets.
Ensure that the fuse or circuit breaker for the outlet is not tripped, and that the wall
switch controlling the outlet (if any) is in the ON position.
Ensure that the equipment you want to stay powered during a power failure is
plugged into the “Battery Backup plus Surge Protection” outlets and NOT the “Surge
Protection” outlets.
Make sure that the equipment plugged into the outlets of the unit are not overloading
the capacity of the unit. Try removing some of the equipment and see if the problem
continues.
The UPS S is operating normally.
The UPS can only operate on battery power for a limited amount of time.
The unit will eventually turn off when the available battery power has been used.
Allow the unit to recharge for 16 hours before continuing use of the unit.
The output waveform is designed for computers and computer-related equipment. It
is not designed for use with motor-type equipment.
Contact APC Technical Support for further troubleshooting.
The UPS s operating normally and using battery power. Once On Battery,
you should save your current work, power down your equipment, and turn the unit
OFF. Once normal power is restored, you may turn the unit back ON and power
your equipment.
The -UPS ES is about to shut off due to a low battery charge condition! When
the unit beeps once every second, the battery has about 2 minutes of power
remaining. Immediately power down your computer and turn the unit OFF. When
normal power returns, the unit will recharge the battery.
Call a qualified electrician for service.
Allow the unit to charge by leaving it plugged into the wall at least 16 hours.
As a battery ages, the amount of runtime available will decrease. You can replace
the battery by ordering one at www.apc.com. Batteries also age prematurely if the
UPS ES is placed near excessive heat.
Problem
Probable Cause
Solution
Specifications
Warranty
Service
Contact InformationPowerstar
Input
Voltage
120 Vrms Nominal
Frequency
47 - 63 Hz
Brownout Transfer
96 Vrms, typical
Over-voltage Transfer
136 Vrms, typical
Output
UPS Capacity (3 outlets)
350 VA / 200 W 500 VA / 300 W
Surge Capacity (6 outlets)
12 Amps (including UPS output)
Voltage
On Battery
115 Vrms + 8%
(step-approximated sine wave)
Frequency - On Battery
50-60 Hz + 1 Hz
Transfer Time
5 ms typical, 8 ms maximum
Protection and Filter AC Surge Protection
Full time, 375 joules
Telephone Surge Protection
Single line (2-wire)
EMI/RFI Filter
Full time
AC Input
Resettable circuit breaker
Battery
Type
Sealed, maintenance-free lead acid
Average Life
8-10
88=-10years depending on the number of discharge
cycles and environmental temperature
Physical
Net Weight
9.20 lb. (4.18 kg.) 13.25 lb. (6.02 kg.)
Size
3.3” (H) x 10.9” (W) x 6.9” (D)
(8.3 x 27.8 x 17.5 cm)
Operating Temperature
+32
o
F to 104
o
F (0
o
C to 40
o
C)
Storage Temperature
+ 5
o
F to 113
o
F (-15
o
C to 45
o
C)
Operating Relative Humidity
0 to 95% non-condensing
Operating Elevation
0 to 10,000 ft (0 to 3,000m)
Safety/Regulatory
Safety Approvals delta power
UL 1778 listed, cUL certified per
CSA standard C22.2 No. 107.1
EMC Compliance
FCC part 68, FCC part 15 Class B
Notice: This device complies with part 15 of
the FCC rules. Operation is subject to the
following two conditions: (1) This device may
not cause harmful interference, and (2) This
device must accept any interference received,
including interference that may cause
undesired operation.
Model
ps
350
500
The standard warranty is 2 years from the date of purchase. standard
procedure is to replace the original unit with a factory reconditioned unit. Customers
who must have the original unit back due to assigned asset tags and set depreciation
schedules must declare such a need at first contact with Technical Support.
will ship the replacement unit once the defective unit is received by the repair
department or cross-ship upon the provision of a valid credit card number. The
customer pays for shipping to , and pays ground freight transportation costs
back to the customer.
Please DO NOT RETURN UPS to the place of purchase under any
circumstances and do not throw .
1. Consult the Troubleshooting section to eliminate common problems.
2. Verify the battery is connected (see
Connect Battery
) and that the Circuit Breaker is
not tripped (see
Troubleshooting
section).
If you still have problems or questions, please contact via the internet or at one of
the phone numbers listed below.
3. Before contacting , please be sure to record the date purchased, UPS model,
and serial number (on bottom of unit).
4. Be prepared to troubleshoot the problem over the telephone with a Technical
Support Representative. If this is not successful, the representative will issue a Return
Material Authorization Number (RMA#) and a shipping address.
Pack the unit in its original packaging. If the original packaging is not available, ask
Technical Support about obtaining a new set. Pack the unit properly to avoid
damage in transit. Never use foam beads for packaging. Damage sustained in transit
is not covered under warranty (insuring the package for full value is recommended).
5. Write the RMA# on the outside of the package.
6. Return the unit by insured carrier to the address given to you by Technical
Support.
Order Replacement Battery
Replace with an qualified battery. Replacement batteries can be ordered from
www.apc.com (valid credit card required). Have you UPS model number
available when ordering. Your model number can be found on the bottom of the unit.
Wall Mounting Template
7.08 in.