17
INSTRUCTIONS PL600/PL1000
1). The transmitter Reaction
Channel/Functions
SW2 switch on
SW2 switch off
2 channel transmitter
(A)Button:
“Open- Stop- Close- Stop”
(B)Button:
“Pedestrian mode”
(A)Button:
“Open- Stop- Close- Stop”
(B)Button: Long Press for other device
turn-on, like garage door system
4 channel transmitter
(A) Button:
“Open- Stop- Close- Stop”
(B) Button:
“Pedestrian mode”
(C) Button: Long Press for other device turn-on,
like garage door system
Or
(D) Button: Long Press for other device turn-on,
like garage door system
(A) Button:
“Open- Stop- Close- Stop”
(B) Button: Long Press for other device
turn-on, like garage door system
(C) Button:
“Pedestrian mode”
Or
(D) Button:
“Pedestrian mode”
Important notice:
(1) Jumper 4:
②
and
③
in place: remote control button (C) usable
; Jumper 4:
①
and
②
in place: remote control button (D)
usable.
(2) Pedestrian mode follows function
“F6-0~F6-5” settings.
Button (C) Usable
Button (D) Usable
3
2
1
3
2
1
2). Transmitter Memorizing and Erasing Process
(1) Transmitter Memoring: Press
“RF LEARN” button for 2 seconds, and the LED3 is on; then press the
transmitter (A) button; the LED3 will blink twice and then be off. The system learning is complete.
(2) Transmitter Memory Erasing: Press
“RF LEARN” button for 5~6 seconds as LED 3 is on, then wait for LED3 off.
4.1.2 Recognition of LED
LED Indication
Descriptions
LED1 Photocells
LED1 will be on when the first pair of the photocells are activated.
LED2 Photocells
LED2 will be on when the second pair of the photocells are activated.
LED3 RF Learning
LED3 will be on when RF-learn button is pressed.
4.1.3 Checking the Gate Movements
1). Release the gearmotor with the release key and move the gate to the middle so that it is free to move in both
opening and closing directions; then lock the gearmotor.
2). Perform the gate opening and closing several times and make sure the gates reaches the limit switch at least 2~3
centimeters before the mechanical stop.
4.2 Programmable Functions Lists
LED Display
Definition
Function
Value
Description
F1
Options of Gate
Opening direction
F1-0
Clockwise Opening
1. The function can adjust the
direction of gate opening.
2. The factory setting is "F1-1".
F1-1
Counterclockwise Opening
F2
Automatic Closing
F2-0
No automatic closing
1. This function can cause the gate
to close automatically after the
paused time.
2. The factory setting is "F2-
2”:
15secs as the pause time.
F2-1
5 seconds
F2-2
15 seconds
F2-3
30 seconds
F2-4
45 seconds
F2-5
60 seconds
F2-6
80 seconds
F2-7
120 seconds
F2-8
180 seconds