19
LED Display
Definition Function Value
Description
Open Partially
(Pedestrian mode)
Pre-flashing
Over current reverse
setting
Open-stop-close-stop
function key
Open Partially function
key
External device control
function key
Photocell 1 function
Photocell 2 function
Photocell test function
Stop connector function
F8
F9
FA
FB
FC
FD
FE
FF
FG
FH
F8-1
F8-2
F8-3
F8-4
F8-5
F8-6
F9-0
F9-1
FA-0
FA-1
FA-2
FA-3
FB-0
FB-1
FB-2
FB-3
FC-0
FC-1
FC-2
FC-3
FD-0
FD-1
FD-2
FD-3
FE-0
FE-1
FF-0
FF-1
FG-0
FG-1
FH-0
FH-1
3seconds
6seconds
9seconds
12seconds
15seconds
18seconds
The flashing light blinks when
the gate starts to move.
The flashing light blinks 3 seconds
before the gate starts to move.
Stop
Reverse 1 second
Reverse 3 second
Reverse to the end
No function in transmitter
B key
C key
D key
No function in transmitter
B key
C key
D key
No function in transmitter
B key
C key
D key
Close
Open
Close
Open
Close
Open
Close
Open
1. The function can adjust the time of opening partially.
2. The factory settingis"F8-2".
1. The factory setting is "F9-1".
1. The factory setting is "FA-3".
2. The reverse function only operate 3 times and then stop.
3. If gate reverses, the auto close function will be cancelled.
1. The factory setting is "FB-0".
1. The factory setting is "FC-1".
1. The factory setting is "FC-2".
1. The factory setting is "FE-0".
1. The factory setting is "FF-0".
1. The factory setting is "FG-0".
2. If the function open
1. The factory setting is "FH-0".
2. Stt
Summary of Contents for PL1000H
Page 1: ...FOR RESIDENTIAL USER MANUAL SLIDING GATE OPENERS PL600H PL1000H 24V DC MOTOR ...
Page 2: ......