INSTRUCTIONS PL600H/PL1000H
22
6) Maintenance and Disposal
The maintenance operations must be performed in strict compliance with the safety directions provided in the manual
and according to the applicable legislation and standard.
In order to have good and safety performances, test the gate-automated system weekly and have qualified
installation personnel to check and maintain the system at least every 6-month.
6.1 Maintenance
Some electronic components and the batteries may contain polluting materials; do not pollute the environment. Make
sure the recycling or disposal systems available under the regulations locally in fore.
PL600H/PL1000H are consist of different types of materials; some of them can be recycled such as aluminum,
plastic, electric cables while some need to be disposed, such as electronic boards.
6.2 Disposal
7) Additional Information
After you have added or removed any devices, the automation system must be tested again according to the
operation mentioned in paragraph 5 “Testing”.
Overheated Back-up Batteries
The radio transmitter does not control the gate,
and the LED on the transmitter does not light up.
The radio transmitter does not control the gate
but the LED on the transmitter lights up.
The maneuver doesn’t start and the LED 1~3 on
the control unit doesn’t flash.
The maneuver doesn’t start and the flashing
light is off.
The maneuver doesn’t start and the flashing
light flashes a few times.
The gate starts but it is immediately followed by
a reverse run.
The maneuver is done but the flashing light does
not work.
The gate only moves a little distance when
pressing the button of the transmitter.
The gate shall be closed instead of opening.
The leaves suddenly stop during moving.
The gearmotor does not run and the relay is
noisy when operating the gate opening and
closing.
●
Check the wiring connection of the batteries.
●
Check to see if the batteries are run out, if necessary replace them.
●
Check to see if the transmitter has been memorized correctly with the
radio receiver.
●
Check the power cord is plugged into the electricity socket.
●
Check to see if the fuses are blown; if necessary, identify the reason
for the failure and then replace the fuses with others having the same
current rating and characteristics.
●
Check the order is actually received. If the order reaches the OPEN
input, the corresponding “OPEN” LED must light up; if you are using
the radio transmitter, the LED on control unit must make two long flashes.
●
Count the flashes and check the equivalent value in table.
●
The selected force could be too low to move the gate. Check if there
are obstacles; if necessary increase the force.
●
Check the hall sensor wiring connection is firm.
●
Activate the “RESET” socket or cut off the AC input power, and cut off
the batteries output for five seconds, then power the whole unit by
connecting the AC and battery terminals
●
Check that there is voltage on the flash light’s terminal during
maneuver; if there is voltage, the problem could be the lamp, so try to
replace the lamp with a new one.
●
Check the wiring connection of the hall sensor is firm.
●
Adjust the direction of gate opening by Programmable Functions;
please refer to “4.2 Programmable Functions Lists”.
●
Check if the “RESET” socket is activated
●
Make sure the wiring connection of the gearmotor is firm.
●
Make sure the hall sensor wiring connection is firm.
●
The GND terminal of the photocells on the PCB must be short-circuited
if no photocells installed.
●
Make sure the fuse is workable.
●
Check if the fuse is burned.
7.1 Adding or Removing Device
7.2 Troubles Shooting
Symptoms
Recommended checks and possible solution