INSTRUCTIONS PL600H/PL1000H
7
Check the following items before going for installation:
Figure 11
Figure 12
3.3 Preparation for Motor Installation
PL600H/PL1000H is not applicable to a gate which is inefficient or unsafe, neither to solve the defects due to incorrect
installation nor poor maintenance.
9). The installed at the left side and at the right site as below:
Gate without rack: the distances indicated in
Figure 12.
332mm
287mm
91mm
216mm
Check the dimensions of the motors as below:
SX
DX
50mm
50mm
50mm
50mm
1). Make sure the weight and dimensions of the gate conform to the operation range of PL600H/PL1000H. Don’t use
PL600H/PL1000H if the gate specifications do not meet the requirements.
2). Make sure the gate structure conform to the criteria of automatic operation and force regulations.
3). Make sure there is no serious friction existing in the opening or closing travel of the gate.
4). Make sure the gate is at horizontal level that the gate will not move aside at any position.
5). Make sure the gate can bear the impact of the motor torque when it is installed on the plate which the surface is
sufficiently sturdy.
6). Make sure that the installation area is not easy to be invaded by flood. If necessary, mount the raised from the
ground.
7). Make sure the photo sensors (optional) are installed on flat surfaces to ensure the two ends of receiving and
transmitting corresponded to each other.
8). Make sure the installation area is suitable to the size of and the area is safe and easy to release the gearmotor.
Summary of Contents for PL1000H
Page 1: ...FOR RESIDENTIAL USER MANUAL SLIDING GATE OPENERS PL600H PL1000H 24V DC MOTOR ...
Page 2: ......