24 INSTRUCTIONS PW220/PW230
3.3 System Learning Process
Connect the master motor wires to M1 terminals and the slave motor wires to M2 terminals correctly. If only one gate is installed,
the motor wires have to be connected to M1 terminals.
In system learning mode, the gates will proceed with the following procedures.
(A) Dual-Gate Mode: Slave Gate closes→ Master Gate closes→ Master Gate opens →Slave Gate opens →Slave Gate closes→
Master Gate closes.
(B) Single-Gate Mode: Master Gate closes→ Master Gate opens→ Master Gate closes.
Notes
: System learning fails and needs to be learned again when an unpredictable interruption occurs.
3.4 Gate Operation
Figure 34
3.5 Gate-moving Logic
(A) In gate-opening phase: The gates stop if the transmitter/push button/key selector is activated, and close when the
transmitter/push button/key selector is reactivated.
(B) In gate-closing phase: The gates stop if the transmitter/push button/key selector is activated, and open when the
transmitter/push button/key selector is reactivated.
(C) In gate-opening or gate-closing phase: For safety purpose, the gates stop if encountering obstacles.
In dual gate installation:
Press the button “A” on the transmitter for dual-gate operation.
Press the button “B” on the transmitter for single-gate
operation.
In single gate installation:
Press the button “A” on the transmitter for single-gate
operation.
Summary of Contents for PW220
Page 1: ......