INTRODUCTION

 

 

Thank you for your purchase of a POWERTRONIX Power Isolation Unit and congratulations on your 
choice. The 

Isolation Station

 series of power isolation units is ideal for applications where medical and 

dental devices require improved electrical isolation and/or reduced leakage current in order to comply 
with existing safety standards, and where sensitive electronic systems require protection from electrical 
power disturbances. 
 

SAFETY SYMBOLS

 

 

 

Warning, dangerous 

voltage 

 

Alternating Current/AC 

 

General warning sign

 

 

Direct Current/DC

 

 

Caution 

 

 

Equipotentiality

 

 

Protective Earth 

(Ground)

 

 

 

Earth (Ground)

 

 

 

Refer to Instruction 

Manual/booklet 

 

 

 AND 

“ON” and OFF (Power) 

Indicator lights  

GREEN, WHITE  

& AMBER

 

Indicator lights  

“Ready for Use”  

 

 

 

 

INSPECTION

 

Remove the power isolation unit from the shipping container and inspect it for shipping damage. 

Do not install or operate the product if it appears to be damaged in any way. If the unit is damaged, notify 
the carrier, and the company that sold you the unit, IMMEDIATELY. 

 

ENVIRONMENTAL ISSUES

 
 

This power isolation unit has environmental requirements similar to other electronic equipment. It 

has been designed for indoor use only, in areas where it will not be exposed to excessive dust or 
moisture. Make certain there is adequate airflow around the unit. Do not place objects on top of or near 
the unit, which could obstruct the air vents. 
 
This equipment may generate, use and can radiate radio frequency energy and, if not installed and used 
in accordance with the instructions, may cause harmful interference to other devices in the vicinity. If this 
equipment does cause harmful interference to other devices, which can be determined by turning the 
equipment off and on, the user is encouraged to try to correct the interference by one or more of the 
following measures. However, there is no guarantee that interference will not occur in an installation.  
 

Summary of Contents for Isolation Station Series

Page 1: ...P2 POWERTRONIX Corporation Page 1 of 10 300VA 3000VA Instruction Manual ...

Page 2: ... shipping damage Do not install or operate the product if it appears to be damaged in any way If the unit is damaged notify the carrier and the company that sold you the unit IMMEDIATELY ENVIRONMENTAL ISSUES This power isolation unit has environmental requirements similar to other electronic equipment It has been designed for indoor use only in areas where it will not be exposed to excessive dust ...

Page 3: ...tics or other flammable gases or liquids WARNING Grounding continuity should be checked periodically NOTE USA and Canada grounding reliability can only be achieved when this equipment is connected to a matching receptacle marked Hospital Only or Hospital Grade WARNING The top and bottom surfaces of the power supply enclosure are not intended to be touched while the power supply is in use While the...

Page 4: ...y standards for the end application WARNING This unit is a multiple socket outlet MSO device When user connects load equipment to Isolation Station MSO the total system becomes a new ME System and user needs to carry out an evaluation to the requirements of IEC 60601 1 standard for the total system POWER CORD REQUIREMENTS Input All power cords must be appropriately approved by testing agencies in ...

Page 5: ...S WITH HIRE CURRENT RATINGS MOUNTING The Isolation Station may be placed horizontally on any flat and stable surface such as a floor or table top For high traffic areas carts and unstable surfaces use of the mounting brackets for all mounting locations is recommended to ensure the stability of the Isolation Station Some versions of the Isolation Station may also be vertically mounted to a wall For...

Page 6: ...s possible to the load equipment Do not use extension cords or surge or filtration devices with the power isolation unit Place all load equipment power switches in the OFF position Plug the power isolation unit into an appropriately sized AC power source Plug the load equipment into the power isolation unit receptacles The load equipment must be connected to the power isolation station unit with a...

Page 7: ...n a returned material authorization RMA number from customer support Products must be returned with transportation charges prepaid and must be accompanied by a brief description of the problem encountered as well as a purchase receipt or other proof of date and place of purchase Please keep your sales receipt or other document showing proof of purchase Attach it to this owner s manual and keep bot...

Page 8: ...ee cloth Do not use any cleaning agent as they may have a corrosive effect Use a soft lint free cloth or the dusting attachment or your vacuum cleaner to dust your power isolation unit Do not expose the power isolation unit to humidity rain sand or excessive heat caused by heating equipment or direct sunlight CONNECTION DIAGRAM ...

Page 9: ...CTION INFORMATION Date Purchased __________________________________________ Part Number __________________________________________ Serial Number __________________________________________ Where Purchased __________________________________________ ...

Page 10: ... its accompanying documentation without obligating POWERTRONIX to update information and or product that has been delivered earlier POWERTRONIX assumes no liability for typographical errors in this documentation POWERTRONIX shall not be liable for technical or editorial errors or omissions contained herein nor for incidental or consequential damages resulting from our furnishing of this material a...

Reviews: