background image

Chapter 5.  Specifications 32

NOTES:

Summary of Contents for 0 ACE2200

Page 1: ...THE ELECTRONIC SYSTEM POWER SPECIALISTS Uninterruptible Power System 400VA 2200VA ...

Page 2: ...Part Number 05141270 Revision C 3 94 ...

Page 3: ...Check your equipment 3 Precautions 3 Overview of Equipment 4 What it looks like 4 Rear Panels American Models 6 Rear Panels International Models 8 User Controls 9 Front Panel Display 9 Chapter 2 INSTALLATION 11 Instructions 11 Installation American Models 11 Installation International Models 15 ...

Page 4: ...er 4 MAINTENANCE 27 Preventive Maintenance 27 Battery Life 27 BatteryRecharging 27 Storing the UPS 27 Regular Maintenance 28 Chapter 5 SPECIFICATIONS 29 Electrical Input 29 Electrical Output 29 Indicators and Controls 30 Physical 30 Chapter 6 TROUBLESHOOTING GUIDE 33 ...

Page 5: ...mpact and manageable It is easy to move install and operate There are no complicated instructions to follow just a few simple tasks to perform UPS Battery Management Another feature is Battery Management which prolongs battery life and speeds recharge time to give you maximum reliability It also gives an early warning of impending battery end of life Communication Capability The UPS has feature ri...

Page 6: ...y analyzing the frequency of the line This Auto Frequency Selection allows the user to use the same equipment even when moving to different locations as long as the voltage remains within the unit s specifi cations No Line No Load Auto Shutdown To prevent the batteries from discharging when the power fails and the load is less than 5 the UPS will shut down automatically You can disable this functi...

Page 7: ...ed damage To file a claim for shipping damage or concealed damage File with the carrier within 15 days of receipt of the equipment Send a copy of the damage claim within 15 days to the place of purchase Precautions Please read all instructions before operating the equipment and save this manual for future refer ence Chapter 1 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contai...

Page 8: ...ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀ...

Page 9: ...ÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ 0N ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ ÀÀÀÀÀÀÀÀÀÀÀÀÀ...

Page 10: ...Although similar the rear panels of the various models have different configurations Find the drawing of the rear panel for your unit and become familiar with it Models ACE1000 ACE1500 Models ACE400 ACE600 Chapter 1 Preparation 6 ...

Page 11: ...Model ACE2200 Model ACE2000 UPS Owner s Manual 7 ...

Page 12: ... similar the rear panels of the various models have different configurations Find the drawing of the rear panel for your unit and become familiar with it Models ACE400i ACE600i Chapter 1 Preparation 8 Models ACE1000i ACE1400i ACE1800i ACE2200i ...

Page 13: ...are user defined switches to configure the UPS OFF is the default position Switch 7 is not defined If any of the switches are changed during UPS operation these changes will not be noticed until the UPS is completely powered off then powered on again Communication Port Also located on all rear panels is the Communication Port DB 9 female connector This port allows the UPS to report its status to a...

Page 14: ...ns may cause harmful interference to radio or television reception which can be determined by turning the equipment off and on The user is encouraged to try to correct any interfer ence by one or more of the following 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on a different circuit than where the...

Page 15: ...American Dip Switch Configurations table below If any switches are changed while the unit is running the changes will not take effect until the unit is completely powered down and then turned back on No Position Function 1 2 OFF 120V 1 ON 2 OFF 127V 1 OFF 2 ON 110V 1 2 ON 120V w extended operating voltage range 3 OFF Enable Site Warning Alarm 3 ON Disable Site Warning Alarm 4 OFF Approx 2 mins bac...

Page 16: ...mputer devices Operation of this equipment in residential areas may cause unacceptable interference to radio and TV reception requiring the operator to take whatever steps are necessary to correct the interference Le prØsent appariel numØrique n Ømet pas de bruits radioØlØctriques dØpassant les limites applicables aux appareils numØriques de la classe A prescrites dans le RØglement sur le brouilla...

Page 17: ...hat the UPS ON OFF Switch is OFF then plug the UPS line cord into the wall outlet NOTE DO NOT plug laser printers into the UPS Plug your load into the UPS using whichever outlets you need UPS Owner s Manual 13 ...

Page 18: ...s to appear on the front panel of the UPS Push the Alarm Silence Reset Button if any red LEDs appear If any red LEDs still appear see Chapter 3 You have now completed installation Allow approximately 24 hours for the UPS to charge the batteries after installation or long storage Without charging the battery indicators and measurements will not be accurate NOTE ON OFF UPS ON OFF Switch ...

Page 19: ... 5 ON Disable 5 load auto shutdown 6 OFF Conditional shutdown delay 5 sec 6 ON Conditional shutdown delay 180 sec 7 OFF Not used 8 OFF Auto frequency selection priority 50Hz 8 ON Auto frequency selection priority 60Hz These are the default values International Dip Switch Configurations Set up the Dip Switches according to the International Dip Switch Configurations table below If any switches are ...

Page 20: ... ON This can damage equipment To establish communication between a UPS and a computer plug the optional UPS Computer Interface Cable into the Port Only use this optional factory supplied cable and software The UPS will operate normally whether or not you use the Communication Port Attach the ACE Battery Box plug into the UPS ACE Battery Box Connection CAUTION Arcing may occur when inserting the pl...

Page 21: ...do not need to unplug the cord from the wall outlet Plug the line cord that you removed from your load in Step 4 into the male inlet on the UPS located at the bottom left corner UPS Owner s Manual 17 S CO O O O O U U PO T 4H 250V Line Cord Male Inlet ...

Page 22: ...PS and one end to your load s male inlet S CO O O O O U U PO T 4H 250V Line Cord Female Outlets Rear of Load Male Inlet DO NOT plug laser printers into the UPS Move the switch to ON Wait several seconds while the UPS performs the initial internal self diagnostics Chapter 2 Installation 18 NOTE ...

Page 23: ...l appear see Chapter 3 If you have more equipment to connect repeat Steps 5 and 6 using the second interconnecting cable If you have connected all of your equipment you have now completed installation Allow approximately 24 hours for the UPS to charge the batteries after installation or long storage Without charging the battery indicators and measurements on the UPS will not be accurate NOTE NOTE ...

Page 24: ...Chapter 2 Installation 20 NOTES ...

Page 25: ...t The test also looks at the utility line to see if the ground is properly connected If there are any problems the front panel LEDs will indicate the problem and the audio alarm will beep twice At the end of the test the audio alarm will sound one short beep This section explains the UPS operation See the Troubleshooting Guide in Chapter 6 for more information Front Panel The Front Panels of all t...

Page 26: ...so flash when the normal line returns until you push reset If the normal line returns before battery shutdown the LED will turn off Middle LED Green This LED will be on when the Line is OK Bottom LED Red This LED will be solid red when the Line is Too Low undervoltage condition and the UPS is in battery operation After the battery backup is used up the LED will flash for 10 minutes It will also fl...

Page 27: ...ault As the battery capacity declines the bar graph reduces with the LEDs turning off from top to bottom Impending Low Battery the top four LEDs are off and the bottom LED red is ON when there is about 2 to 5 minutes of battery backup left Battery exhausted before line returns the bottom LED red will flash for 10 minutes Line returns the bottom LED red turns off and the remaining four green LEDs l...

Page 28: ...he load current or load watts whichever is higher in steps Overload the top red LED turns on when load current or watts exceeds full load When normal load is restored this top LED will turn off The green Communication LED will turn on after the UPS receives a command code from a computer to establish serial communication This LED will flash during data transfer via the Comm Port The Communication ...

Page 29: ... from operating ON OFF Switches 1 2 3 4 5 6 and 8 are user defined switches Off is the default position See The Dip Switch Configuration tables in the Installation section for explanations of each configuration OFF ON 1 2 3 4 5 6 7 8 When the optional Interface Cable is plugged into this port the UPS and a computer can communi cate See the Communication Port Configuration Table in this section for...

Page 30: ...Indicates that the battery has internal closing with pin 4 less than 2 or 5 minutes of backup time left 6 Output simulated contact AC Input Failure Indicates absence of normal opening with pin 4 Input 7 Input common or RS 232 Remote Output OFF ON UPS output can be turned low open or RS 232 high OFF by maintaining low or common UPS output output returns when pin is high or open if normal AC Input i...

Page 31: ...er a power failure Com plete recharging can take up to 24 hours if the battery is fully discharged However most charging is done in less than 8 hours Storing the UPS If you are going to store the UPS unplugged turn the UPS ON OFF Switch OFF If you store the UPS for a long period recharge the battery every six months by plugging the UPS into the utility power and turning the UPS ON OFF Switch ON If...

Page 32: ...maintenance other than battery charging for units not in service If there are any problems repairs must be done by the factory or factory authorized service locations Please contact a sales representative or technical service if you have any questions or problems ...

Page 33: ...ler Electrical Output Power Levels 400 2200VA see Model Specifi cations table On Line Efficiency 96 Regulation On Line 6 10 within Computer Business Equipment Manufactur ers Association s Guidelines 10 15 using extended range Regulation On Battery American 117V nominal International 230V nominal 5 Voltage Wave Shape Sine Wave 3 distortion with linear load Over Current Protection On Line Resetable ...

Page 34: ... 320 receptacles Noise Filtering MOVs and line filter for normal and common mode noise Indicators and Controls Serial Communication Intelligent serial communication to provide alarms with history measured parameters self test and many other features Front Panel Interface Ergonomic indicators including Wiring Fault Battery Service Communication Operation System Normal Bar graphs for Input Level Bat...

Page 35: ... 17 0 x 39 9 11 1 ACE600i4 50 60 2302 6003 2 6 4 5 x 6 7 x 15 7 28 11 4 x 17 0 x 39 9 12 7 ACE1000i4 50 60 2302 10003 4 3 7 x 9 x 16 7 49 5 17 8 x 22 9 x 42 4 22 5 ACE1400i4 50 60 2302 14003 6 1 7 x 9 x 16 7 54 17 8 x 22 9 x 42 4 24 5 ACE1800i5 50 60 2302 18003 7 8 7 x 9 x 16 7 28 17 8 x 22 9 x 42 4 12 7 ACE2200i5 50 60 2302 22003 9 6 7 x 9 x 16 7 28 17 8 x 22 9 x 42 4 12 7 ACE Battery Box 48V 7 x...

Page 36: ...Chapter 5 Specifications 32 NOTES ...

Page 37: ... If alarm continues to sound contact Powervar s service center Top LED above AC Line is high UPS in Correct input voltage if Input symbol is SOLID battery operation possible or be prepared to RED lose power to load in approx 2 or 5 minutes after Impend ing Low Battery LED turns on Top LED above AC Battery is discharged and Wait until power returns to Input symbol is FLASHING UPS has stopped normal...

Page 38: ... the fault condi tion Follow your local codes Bottom LED above 2 or 5 minutes of battery Be prepared to lose AC Battery symbol is SOLID backup left with normal power to your load s RED load and enough charge Low Battery Alarm does not Dip Switch 4 is OFF Put Dip Switch 4 ON give enough warning before Batteries need charging Keep UPS plugged into battery runs low wall socket for at least 24 hrs Bat...

Page 39: ...The remaining pages were left blank intentionally ...

Page 40: ......

Reviews: