Diagram Without Optional Electronic Display
1
H
H
N
N
PRESSURE
SWITCH
TEMPERATURE
SWITCH
SPARK
P1
P3
P2
E1
GND
120
PILOT
ELECTRODE
ASSY
PS
TS
TS1
TS2
FV
MOT
1
2
3
4
5
1
2
3
1
1
2
SCHEMATIC
CONNECTION DIAGRAM
W
V 4460E C
ONTR
OL
N
H
G
120 VAC
INDUCER
3 x 2 CONNECTOR
BL
R
Y
W
BK
G
5
4
3
2
1
<
>
BK = BLACK
BL = BLUE
G = GREEN
R = RED
W = WHITE
Y = YELLOW
1
2
W
W
TS2
BK
BK
TS1
FV
1
2
3
120
NEUT
GR
OUND
120
VA
C
CAUTION!..Label.all.wires.prior.to.disconnection.when.servicing.controls ..Wiring.errors.can.cause.improper.and.
dangerous.operation ...VERIFY.PROPER.OPERATION.AFTER.SERVICING!
17
Wiring
If.local.codes.permit,.the.water.heater.may.
be.connected.to.electric.service.with.the.
power.cord.provided.(DO.NOT.use.an.
extension.cord) ..A.grounding.receptacle.is.
required .
If.local.codes.do.not.permit.the.use.of.
cord.connections,.a.120.V,.50/60.Hz.
power.supply,.with.suitable.disconnecting.
means,.must.be.connected.to.the.black.and.
white.leads.in.the.heater.control.enclosure ..
A.knock-out.hole.is.provided.to.permit.use.
of.conduit.or.metal-clad.cable.connectors ..
The.maximum.current.draw.is.
approximately.5 .0.amps ..
The.water.heater.must.be.electrically.
grounded.in.accordance.with.local.
codes,.or,.in.the.absence.of.local.codes,.
in.accordance.with.latest.edition.of.the.
National.Electric.Code.ANSI/NFPA.No ..
70 ..Refer.to.the.figures.below.for.water.
heater.internal.wiring .
NOTE
:.It.is.not.recommended.that.this.
unit.be.installed.on.a.GFCI.circuit .