1-5 Overview 

FRONT VIEW 

 

 

REAR VIEW 

 

 

 

Input switch 

 

 

Fault indicator 

 

USB communication port 

 

MUTE/FUNCTION  button:  to  silence  the 

buzzer 

 

RS232 communication port 

 

Expansion slot for communication boards 

 

SELECT  button:  to  toggle  the  different 

status screens in LCD display 

 

Output IEC 10A sockets 

 

ON/OFF button: to turn on or off the 
outputs 

 

 

Input 16A plug 

 

LCD display 

 

 

 

 

Mains indicator 

 

 

 

 

 

 

Summary of Contents for PDU RC-16A

Page 1: ...Power Distribution Unit Version 1 0 User Manual PowerWalker PDU RC 16A...

Page 2: ...1 1 1 Package Contents 1 1 2 Safety 1 1 3 Disposing of PDU 1 1 4 Function 1 1 5 Overview 2 2 Installation 3 2 1 Rack Mounting 3 2 2 Connections 3 3 Operation Display 4 3 1 Panel Overview 4 3 2 Operati...

Page 3: ...in a temperature and humidity controlled indoor environment Ambient temperature must not exceed 50 C The PDU is not intended for outdoor use 1 3 Disposing of PDU The PDU contains internal components t...

Page 4: ...MUTE FUNCTION button to silence the buzzer RS232 communication port Expansion slot for communication boards SELECT button to toggle the different status screens in LCD display Output IEC 10A sockets...

Page 5: ...n a 19 inch bay with a depth of 600mm at the desired height in the cabinet uprights Secure the device adequately to cabinet with four screws 2 2 Connections For connecting the PDU plug the input to th...

Page 6: ...et icon on output on icon off output off icon blinking output overload alarm overload or output shutdown due to overload Fault code please check section 3 2 4 for detailed codes 3 2 Operation The LCD...

Page 7: ...on The displayed information is switched as below order Total input voltage input current input voltage output current for each active numerical plug and fault codes Information LCD Display Input Volt...

Page 8: ...one Turn on selected output socket To switch on a numerical output socket you have to switch to specific plug number shown on left corner by keep pressing SELET button Then press ON OFF button 1 to 2...

Page 9: ...ound again If one or more alarms occur after buzzer has been mute the buzzer will sound again Function Operation It s to switch displayed information on specific output The displayed information is ou...

Page 10: ...N 0 5s OFF S06 Immediate shutdown on Output 6 Blinking OFF 0 5s ON 0 5s OFF S07 Immediate shutdown on Output 7 Blinking OFF 0 5s ON 0 5s OFF S08 Immediate shutdown on Output 8 Blinking OFF 0 5s ON 0 5...

Page 11: ...utput 3 ON OFF ON L04 Lock for overload on Output 4 ON OFF ON L05 Lock for overload on Output 5 ON OFF ON L06 Lock for overload on Output 6 ON OFF ON L07 Lock for overload on Output 7 ON OFF ON L08 Lo...

Page 12: ...68KVA at 230V Overload Protection 16A Breaker Output Nominal Output Voltage 220V 230V 240V Rated Output Voltage 184 300V Output Connections 8 IEC C13 Output Current Accuracy 0 1A Physical Dimensions...

Reviews: